21
6.2.5
PIPELINE
LOADING PUMP / SUPPLY PUMP
BS-01
18)
Operation pump ..........................
Setting of trunk line operating mode.
19)
*
Loading program ...................
Setting of the long-distance buffer loading program.
*
Clock program .......................
Setting the long-distance line operating times.
*
Buffer target ..........................
Setting the target buffer temperature (recommended setting up to a maximum of 70 °C).
20)
*
Buffer min .............................
Setting the lowest temperature at the pipeline buffer TOP (T3).
back to the costumer level .......................
look at Chapter 6.2
INFO
*
The menu buttons are only visible if the long-distance line function LAP is activated in the commissioning menu.
18)
Auto
............................. The long-distance line function is controlled fully automatically.
Off
................................ The trunk line function is switched off.
Permanent
................... The pipeline pump runs continuously.
19)
Full
............................... The buffer is loaded until the target buffer temperature is reached at the TOP buffer sensor (T3) and the temperature
difference to the BOTTOM buffer sensor (T2) is only 10°C (standard setting).
Part
.............................. The buffer is loaded until the target buffer temperature is reached at the TOP buffer sensor (T3).
20) If the set minimum buffer temperature at the TOP buffer sensor (T3) is not reached, the buffer is automatically loaded again according to
the set loading program FULL or PARTIAL to the set buffer target temperature.
Attention:
The HKR 0-2 release must be ON in the detailed display. (contact FFR on the wall unit).
6.2.6
APP
BS-03
21)
Netwok .........................................................
Connect to the Internet with YES (Accepted Terms of Use).
22)
W-LAN visibility ............................................
Activation of W-LAN visibility.
Serialnumber ................................................
Enter the boiler serial number.
Key...............................................................
Displays the security key recommended by GUNTAMATIC.
Hot water display ..........................................
Determines which hot water tank is visualized online.
Chart interval ................................................
Defines the update interval of the online diagrams.
Data update .................................................
Defines the update interval for the online boiler data.
23)
File size recording ........................................
Specifies the maximum size of the recording file (1 MB = approx. 1 day).
Storage rate recording ..................................
Specifies the interval for saving the recording data.
back to the costumer level .......................
look at Chapter 6.2
INFO
21)
The boiler must be connected to the Internet router using a network cable.
22)
If there is no internet connection and activated WiFi visibility, the boiler can be reached internally via the WiFi of the internet router.
23)
A recording can be started online on the APP, which is automatically sent to the e-mail address saved under Contacts after the set
file size has been reached.