30
4.1
Heating system electrical connections
BS-01
Mains connection
•
230 VAC, 50 Hz, 13 A fuse
Ausstattung Standard
•
Boiler control panel
(BCE)
•
Boiler circuit board
(230 VAC)
•
Fault signal output
(24VDC 200mA)
•
Safety temperature limiter
(STL)
•
Boiler sensor
(KVT20
Ω
)
•
Flue gas temperature sensor
(thermocouple)
•
Oxygen sensor
(12V DC)
•
Flue draught fan
(230V AC)
•
Grate cleaner motor
(230V AC)
•
TKS 1
(firebox and ash box door switch, 24VDC)
•
Stoker drive motor G1
(230V AC)
•
Outfeed drive motor A1
(230 VAC)
•
Outfeed blower A2
(230 VAC)
•
Stoker sensor
(PT1000
Ω
)
•
Filling Sensor
(12VDC)
•
Ignition fan
(230V AC)
•
Boiler enabling switch
(emergency off)
•
HP0 output
(230 VAC)
•
Reflux mixers
(230 VAC)
Optional equipment
•
Pump outputs
(230 VAC)
•
Mixer valve outputs
(230 VAC)
•
sensor entrance
(KVT 20
Ω
)
•
anlaloug equipment for furnace
•
Digital remote station
Restistances
Temp.
KVT20 (
Ω
)
-16°C
1434
Ω
-8°C
1537
Ω
-4°C
1590
Ω
0°C
1644
Ω
10°C
1783
Ω
20°C
1928
Ω
30°C
2078
Ω
40°C
2234
Ω
50°C
2395
Ω
60°C
2563
Ω
70°C
2735
Ω
80°C
2914
Ω