T-4
“GSP-1100” CONTROL PANEL LAY-OUT
OPERATION
Local Control Devices
Externally, the Gullco “GSP-1100” controls have switching for Forward/Neutral/Reverse and
Run/Stop, as well as a speed control potentiometer.
= “STOP” - This over-rides all other controls and when activated will apply
regenerative breaking to the motor to bring it to a dead stop, and will disallow any
further operation of the motor while ever it is in this state. This position will also reset
an error code once the fault has been rectified.
= “RUN” - This removes the “STOP” command and allows the control to assume an
operational status.
= “FORWARD” - When the switch is in this position, the control will drive the motor in
the Forward direction when so permitted.
= “NEUTRAL” - When the switch is in this position, the control will not drive the motor
in either direction.
Command Forward Motion
Speed Adjustment
Counter-Clockwise = Slower
Clockwise = Faster
Neutral
Command Reverse Motion
Control in Run Mode
Diagnostic LED
(Behind Screw)
Control in Hold (Stop) Mode