background image

 

3

6. 

Add  distilled  water  in  each  cell  until  battery  acid  reaches  levels  specified  by  the 

battery manufacturer, if applicable.  Do not overfill.  For a battery without cell caps, 

carefully follow the manufacturer’s recharging instructions. 

7. 

Never allow the ring terminals to touch each other. 

8. 

NEVER

 charge a frozen battery. 

9.  

Please be sure the DC system to which the charger is connected is not drawing 

excessive current from the battery for extended periods of time while the charger is 

operating.  This is important to ensure the charger correctly transitions through each 

charging stage to finish with the float voltage level.  If the DC system is drawing 

continuous current while charging, reduced life or damage to the battery may occur. 

 

 

 

AC Connection and Grounding Precautions 

DANGER 

DO NOT OPERATE THIS CHARGER WITH A TWO BLADED ADAPTER PLUG OR 

EXTENSION CORD.  DOING SO CAN RESULT IN SERIOUS PERSONAL INJURY. 

AFTER  SECURING  THE  BATTERY  CONNECTIONS,  PLUG  THE  AC  LINE  CORD 

INTO AN AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT 

CIRCUIT INTERRUPTER (GFCI) BREAKER.

  

 

CAUTION:

 

To reduce the risk of shock, connect only to a properly grounded outlet. 

NOTE:

  AC Line Cord color coding is EU style.  Line = Brown, Neutral = Blue, Ground = 

Green

 

2. INSTALLING THE CHARGER 

 

Choosing Charging Location 

The charger should have at least eight inches of unobstructed area on all sides of the 

unit for effective cooling.  The case of this charger will become warm during operation. 

Because the charger is convection cooled (airflow over the back of the charger), the 

optimum  mounting  position  for  the  charger  is  vertical.  Mounting  on  its  back  on  a 

horizontal surface may cause the charger to slightly reduce amperage output due to the 

thermal  protection  built  in.  Do  not  install  the  charger  on  carpeted,  upholstered,  or 

varnished surfaces. 

Mounting the Charger

 

1. 

Use corrosion resistant ¼” dia. bolts, backed by a flat washer, and secured to the 

mounting surface with a split-ring lock washer. 

2. 

Hold the charger to the mounting surface and mark the holes. 

3. 

Remove the charger and drill the mounting holes. 

4. 

Align the charger and assemble the mounting hardware. Secure. 

Summary of Contents for Trolling Charger 2613A

Page 1: ...r battery s life in applications where it is stored for long periods of time They are 3 stage electronic completely automatic lightweight silent battery chargers and each output produces 12 Volts DC a...

Page 2: ...rs the eye flood the eye with cold running water for at least ten minutes and get medical attention 5 Never smoke or allow an open flame in the vicinity of the battery 6 Do not drop a metal tool onto...

Page 3: ...CORD INTO AN AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER GFCI BREAKER CAUTION To reduce the risk of shock connect only to a properly grounded outlet NOTE AC Line Cord c...

Page 4: ...r 5 amp bank is 60AH The recommended maximum battery size per 10 amp bank is 120AH 2613A Connections Model Output Volts Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max...

Page 5: ...5 2613A Connections Diagram 2 2613A used in a 24V system To use a 2613A in a 36V system connect all 3 outputs in series...

Page 6: ...del Output Volts Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max 2620A 12 24 10 10 2 6 6 9 6 x 7 x 2 6 115VAC 50 60Hz 5 Amps Diagram 3 2620A 10 10 Amps used with 2 ind...

Page 7: ...Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max 2623A 12 24 10 5 10 3 6 6 6 13 x 7 x 2 6 115VAC 50 60Hz 6 25 Amps Diagram 4 2623A 10 5 10 Amps used with 3 independent...

Page 8: ...n parallel with output 1 3 Output 1 and 3 may be connected in series for a 24 V system the engine start output Output 2 may NOT be connected in series with output 1 and 3 2623A Connections Diagram 5 2...

Page 9: ...10 10 10 3 6 6 6 13 x 7 x 2 6 115VAC 50 60Hz 7 5 Amps Diagram 6 2631A 10 10 10 Amps used with 3 independent 12V Batteries NOTE The 2631A can be used on 3 12 volt batteries a 24V system or a 36 volt sy...

Page 10: ...rb the last 10 of charge as quickly as possible without becoming overheated If both lights stay on longer than 24 hours refer to Problem 2 in the troubleshooting section in this manual When the batter...

Page 11: ...he last 10 of charge as quickly as possible without becoming overheated If both lights stay on longer than 24 hours refer to Problem 2 in the troubleshooting section in this manual When the battery ap...

Page 12: ...tery charger 1 Turn off all DC equipment while charging 2 Load test the batteries and replace if necessary 3 Apply a higher AC voltage source or reduce the length of the extension cord 4 Check battery...

Page 13: ...pment does cause harmful interference to radio or television reception which can be determined by turning this equipment off and on the user is encouraged to try to correct the interference by one or...