6. SPECIFICATIONS 

Model 

Output 

Volts 

Output 

Amps 

Banks  DC Cable 

Size 

Size (inches) 

L x W x H 

Input Volts 

Input 

Amps Max 

2613A  12/24/36

 

5/5/5 

6’/4’/4’ 

9.6 x 7 x 2.6 

115VAC 

50/60Hz 

3.5 Amp 

2620A 

12/24 

10/10 

6’/6’ 

9.6 x 7 x 2.6 

115VAC 

50/60Hz 

5 Amps 

2623A  *12/24 

10/5/10 

6’/6’/6’ 

13 x 7 x 2.6 

115VAC 

50/60Hz 

6.25 Amps 

2631A  12/24/36  10/10/10 

6’/6’/6’ 

13 x 7 x 2.6 

115VAC 

50/60Hz 

7.5 Amps 

FCC Class A EMC Notice 

This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection 

against harmful interference when the equipment is operated in a commercial environment.  This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications.  

Operation of this equipment in a residential area is likely to case harmful interference in which case 

the user will be required to correct the interference at his own expense. 

If  this  equipment  does  cause  harmful  interference  to  radio  or  television  reception,  which  can  be 

determined  by  turning  this  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the 

interference by one or more of the following measures: 

---Reorient or relocate the receiving antenna. 

---Increase the separation between the equipment and receiver. 

---Connect the equipment into an outlet on a circuit different from that to which the 

    receiver is connected. 

LIMITED WARRANTY 

For  two  (2)  years  from  the  date  of  purchase,  The  Guest  Co.  will,  at  its  discretion,  repair  or 

replace  for  the  original  consumer,  free  of  charge,  any  parts  found  defective  in  material  or 

workmanship. 

This product is guaranteed for life against water damage. 

Proof of purchase is required: A computerized register receipt is required. Hand-written receipts 

are not accepted for warranty proof of purchase. 

There  is  no  other  expressed  warranty.  Implied warranties, including those of merchantability 

and fitness for a particular purpose, are limited to one year from the date of purchase. This is 

the exclusive remedy and consequential damages are excluded where permitted by law. 

 The Guest Co.    

 

 

 

 

Tel: (203) 235-4421  Fax: (203) 235-0039 

95 Research Parkway    

  

 

 

 

 

  Email: 

[email protected]

     

Meriden, CT 06450, USA  

 

 

 

 

          Website: 

www.guestco.com

 

 

727759 Rev F 

Summary of Contents for Trolling Charger 2613A

Page 1: ...r battery s life in applications where it is stored for long periods of time They are 3 stage electronic completely automatic lightweight silent battery chargers and each output produces 12 Volts DC a...

Page 2: ...rs the eye flood the eye with cold running water for at least ten minutes and get medical attention 5 Never smoke or allow an open flame in the vicinity of the battery 6 Do not drop a metal tool onto...

Page 3: ...CORD INTO AN AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER GFCI BREAKER CAUTION To reduce the risk of shock connect only to a properly grounded outlet NOTE AC Line Cord c...

Page 4: ...r 5 amp bank is 60AH The recommended maximum battery size per 10 amp bank is 120AH 2613A Connections Model Output Volts Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max...

Page 5: ...5 2613A Connections Diagram 2 2613A used in a 24V system To use a 2613A in a 36V system connect all 3 outputs in series...

Page 6: ...del Output Volts Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max 2620A 12 24 10 10 2 6 6 9 6 x 7 x 2 6 115VAC 50 60Hz 5 Amps Diagram 3 2620A 10 10 Amps used with 2 ind...

Page 7: ...Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max 2623A 12 24 10 5 10 3 6 6 6 13 x 7 x 2 6 115VAC 50 60Hz 6 25 Amps Diagram 4 2623A 10 5 10 Amps used with 3 independent...

Page 8: ...n parallel with output 1 3 Output 1 and 3 may be connected in series for a 24 V system the engine start output Output 2 may NOT be connected in series with output 1 and 3 2623A Connections Diagram 5 2...

Page 9: ...10 10 10 3 6 6 6 13 x 7 x 2 6 115VAC 50 60Hz 7 5 Amps Diagram 6 2631A 10 10 10 Amps used with 3 independent 12V Batteries NOTE The 2631A can be used on 3 12 volt batteries a 24V system or a 36 volt sy...

Page 10: ...rb the last 10 of charge as quickly as possible without becoming overheated If both lights stay on longer than 24 hours refer to Problem 2 in the troubleshooting section in this manual When the batter...

Page 11: ...he last 10 of charge as quickly as possible without becoming overheated If both lights stay on longer than 24 hours refer to Problem 2 in the troubleshooting section in this manual When the battery ap...

Page 12: ...tery charger 1 Turn off all DC equipment while charging 2 Load test the batteries and replace if necessary 3 Apply a higher AC voltage source or reduce the length of the extension cord 4 Check battery...

Page 13: ...pment does cause harmful interference to radio or television reception which can be determined by turning this equipment off and on the user is encouraged to try to correct the interference by one or...