![Gude GGH 10 Translation Of The Original Instructions Download Page 13](http://html.mh-extra.com/html/gude/ggh-10/ggh-10_translation-of-the-original-instructions_2277345013.webp)
Introduction
Please read thoroughly this operation manual and
attached safety instructions to enjoy your new gas hot air
turbine. We further recommend to retain the operation
manual for future references. We reserve right to make
technical changes for the purpose of improvement in the
course of continuous product development.
This is the original operation manual.
Device description (figure A/B)
1.
Fan
2.
Shell
3.
Base
4.
Handle
5.
Piezo-ignition button
6.
ON/OFF switch
7.
Reduction valve
8.
Gas hose/reduction valve connection
9.
Gas hose/heater connection
10.
Reduction valve/gas cylinder connection
11.
Gas valve button
12.
Gas cylinder valve
Technical data
GGH 10
Connection:
230V~50Hz
Heating power:
10 kW
Consumption:
about 0.73 kg/h
Operating pressure:
300 mbar
Turbine capacity:
500 m³/h
Type of gas:
propane/butane
Length of power cable:
2m
Degree of protection:
IPX4
Weight:
5,4kg
GGH 10 INOX
Connection:
230V~50Hz
Heating power:
10 kW
Consumption:
about 0.73 kg/h
Operating pressure:
300 mbar
Turbine capacity:
500 m³/h
Type of gas:
propane/butane
Length of power cable:
2m
Degree of protection:
IPX4
Weight:
5,5kg
Nominal heat output
Pnom
10kW
Minimum heat output (indicative)
Pmin
-
Maximum continuous heat output
Pmax
-
At nominal heat output
elmax
-
At minimum heat output
elmin
-
In standby mode
elSb
-
Single stage heat output and no room
temperature control
yes
With mechanic thermostat room
temperature control
-
GGH 17 INOX
Connection:
230V~50Hz
Heating power:
17 kW
Consumption:
about 1.24 kg/h
Operating pressure:
500 mbar
Turbine capacity:
500 m³/h
Type of gas:
propane/butane
Length of power cable:
2m
Degree of protection:
IPX4
Weight:
7kg
Nominal heat output
Pnom
17kW
Minimum heat output (indicative)
Pmin
-
Maximum continuous heat output
Pmax
-
At nominal heat output
elmax
-
At minimum heat output
elmin
-
In standby mode
elSb
-
Single stage heat output and no room
temperature control
yes
With mechanic thermostat room
temperature control
-
General safety instructions
Read and observe all instructions contained herein before
commissioning and operation of the device.
Keep the safety instructions for future reference!
Only use outdoors and away from combustible materials.
Safe work
Keep your workplace tidy!
Disorder on workplace may result in injuries.
Consider surrounding conditions!
Do not expose to rain.
Do not use in moist or wet environment.
Provide good lighting.
Do not use close to flammable liquids or gases (except for
substances required for operation - here propane/butane).
Keep other persons in a safe distance!
Other persons, particularly children, may not touch the
device and power cable. Keep them in a sufficient distance
from your workplace.
Store your device properly!
The device, if not used, should be stored in a dry and
closed space, out of reach of children.
Do not overload your device!
You will work better and more safely if the device is used
at performance power for which it is designed to.
Use correct device!
Do not use the device for purposes other than intended.
Secure your device correctly!
Connect your device according to instructions in
"Assembly" section.
Take care of your tools!
Observe maintenance directions and instructions.
Check tool cable regularly and ask an authorized specialist
to replace the same if damaged.
Check extension cable regularly and replace, if damaged.
Keep handles dry, without traces of oils and greases.
Be careful!
Be aware of what you are doing. Approach your work with
sound mind. Do not use the device if you are tired.
Check the device for damage!
Before use, check thoroughly all safeguards and slightly
damaged parts if they are still functioning properly.
Check whether rotary parts operate freely and not jammed
or damaged.
All parts must be installed properly and must comply with
conditions so that perfect operation of the device is
ensured.
Gas heater
GGH 10 INOX
Itemnumber
85005
Heat output
Rated heat output
Pnom
10 kW
Minimum heat output (indicative)
Pmin
- kW
Maximum continuous heat output
Pmax
- kW
Fuel
Please select fuel type
[gaseous]
[G30]
Space heating emission (*)
NO
x
93,25 [mg/kWh
input
]
(GCV)
Additional power consumption
At rated heat output
elmax
- kW
At minimum heat output
elmin
- kW
In standby mode
elSB
- W
Power requirement of pilot flame
Power requirement of pilot flame
(if present)
Ppilot
0 kW
Thermal efficiency (NCV)
at rated heat output
η
th, nom
100%
at minimum heat output (guide value)
η
th, min
- %
Type of heat output/room temperature control (select one)
Single-stage heat output without room temperature control
x
Two or more manual stages without room temperature control
-
With room temperature control using mechanical thermostat
-
With electronic room temperature control
-
Electronic room temperature control with daily timer
-
Electronic room temperature control with weekly timer
-
Other control options (multiple selection possible)
Room temperature control using presence detection
-
Room temperature control using open window detection
-
With remote control option
-
With adaptive switch-on control
-
With operating time limit
-
With “Black Bulb” temperature sensor, black
-
Space heating annual efficiency
η
s: 90%
Energy Efficiency Index
-
Energy Efficiency Class
A
(*) NO
x
= Nitrogen oxides