Expert Power Control 1100/1101

Safety Advice

1

Safety Advice

The device must be installed only by qualified personnel according to the following installation and operating instructions. 
The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equipment
that may cause personal injury or material damage.
The device contains no user-maintenable parts. All maintenance has to be performed by factorytrained service personnel.
Check if the power cord, the plug and the socket are in proper condition.
The device can be connected only to 230V AC (50 or 60 Hz) sockets.
Always connect the device to properly grounded power sockets. 
The device is intended for indoor use only. Do NOT install them in an area where excessive moisture or heat is present.
Because of safety and approval issues it is not allowed to modify the device without our permission.
Please note the safety advises and manuals of connected devices, too.
The device is NOT a toy. It has to be used or stored out or range of children.
Packaging material is NOT a toy. Plastics has to be stored out of range of children. Please recycle the packaging materials.
In case of further questions, about installation, operation or usage of the device, which are not clear after reading the manual,
please do not hesitate to ask our support team.

Please, never leave connected equipment unattended, that can cause damage (e.g. iron heater, etc.).

2

Description

The  Expert  Power  Control  1100/1101  facilitates  the  remote  switching  of  electrical  devices  via  a  TCP/IP  network.  For
installation, the device is simply connected to a power supply and to the local network.
Operation  and  configuration  are  made  by  a  webinterface.  Additionally,  the  device  can  be  switched  directly  buttons  at  the
housing, via SNMP or http commands, integrated in customer made applications.

An energy meter displays  the energy consumption of  the connected  device  and  a  lot  of  other  electrical  information.  These
informations are displayed via webinterface and SNMP.

A  temperature  sensor  or  a  hybrid  sensor  (temperature  and  humidity)  can  be  connected  to  the  Expert  Power  Control

1100/1101.

A watchdog function for each power port is implemented.

3

Hardware

3.1

Content of delivery

Included in delivery are:

Expert Power Control 1100/1101

Power supply cable , if Expert Power Control 1101

Quick installation guide

Summary of Contents for Expert Power Control 1100

Page 1: ...2012 Gude Analog und Digitalsysteme GmbH Expert Power Control 1100 1101...

Page 2: ...Expert Power Control 1100 1101 2012 Gude Analog und Digitalsysteme GmbH 06 08 2012...

Page 3: ...uration via webinterface 4 3 1 Configuration Power Ports 8 4 3 2 Watchdog 9 4 3 3 Configuration IP Address 10 4 3 4 Configuration IP ACL 11 4 3 5 Configuration HTTP 12 4 3 6 Configuration Messages 13...

Page 4: ...4 Table of content Expert Power Control 1100 1101 2012 Gude Analog und Digitalsysteme GmbH 20 6 4 Factory settings Chapter 7 Support 20 Chapter 8 Contact 20 Chapter 9 Declarations of conformity 21...

Page 5: ...stics has to be stored out of range of children Please recycle the packaging materials In case of further questions about installation operation or usage of the device which are not clear after readin...

Page 6: ...outlet The machine starts and is ready for operation after a short moment The LEDs should be lit 2 Plug the network cable into the Ethernet port on the front of the unit and connect it to your networ...

Page 7: ...to install firmware updates and to reset Expert Power Control 1100 1101 to its factory settings Activate bootloader mode of Expert Power Control 1100 1101 and run GBL_Conf exe The program will look a...

Page 8: ...r Port 4 3 1 2 Initialization Status Here can be the status of the Power Ports defined that should be attained after the device has been turned on remember last state on off 4 3 1 3 Initialization Del...

Page 9: ...g at the moment waiting for first ping reply Red text Watchdog is active and does not receive ping replies any longer When watchdog is activating it waits of a first ping reply During this time the in...

Page 10: ...e netmask of Expert Power Control 1100 1101 All changes need a restart of the firmware to get valid 4 3 3 4 Gateway Here you can change the standard gateway of Expert Power Control 1100 1101 All chang...

Page 11: ...er Here you can activate the IP Access Control List IP ACL of Expert Power Control 1100 1101 If IP ACL is active DHCP and SNMP only work if all necessary servers and clients are registered in this lis...

Page 12: ...e HTTP Password Password protected access can be activated here In this case a user and an admin password have to be defined Passwords have a maximum lengths of 15 characters Administrators are author...

Page 13: ...revents that too much messages are generated when a sensor value is jittering around a sensor limit The following example shows the behaviour for a temperature sensor and a hysteresis value of 1 An up...

Page 14: ...col of the Expert Power Control 1100 1101 4 3 7 4 Community private Here you can enter the SNMP private community 4 3 7 5 Download SNMP MIB Here you can download the Expert Power Control 1100 1101 MIB...

Page 15: ...SNMP read requests and the private community to SNMP write requests You can see the SNMP communites like read write passwords SNMP v1 and v2 transmit the communities without encryption Therefore it i...

Page 16: ...8 1 Enable Syslog Here you can activate Syslog of Expert Power Control 1100 1101 4 3 8 2 Syslog Server IP If syslog is active enter here the IP address of you Syslog server 4 3 8 3 Syslog Port If sys...

Page 17: ...lor of the on off LED at the front green on red off 5 2 Switching by Webinterface Go to the website of Expert Power Control 1100 1101 Enter the IP address of Expert Power Control 1100 1101 into the ad...

Page 18: ...5 3 Sensor Connect the temperature sensor with the sensor connector at the front of the device If it is connected exactly the recent temperature is displayed in the login window in the switching windo...

Page 19: ...lt settings by running the program GBL_Conf exe If the device runs already press the buttons select and ok for three seconds The bootloader mode of Expert Power Control 1100 1101 is indicated by BOOT...

Page 20: ...must be started in bootloader mode Besides that the program GBL_Conf exe is required Run GBL_Conf exe and select the device whose settings should be restored Then click on Program Device Reset to Fab...

Page 21: ...ichtlinie Low Voltage Electrical Equipment 93 68 EWG 93 68 EEC CE Kennzeichnung CE marking und dass die nachstehenden Europ ischen Normen zur Anwendung gelangt sind and comply with the following europ...

Page 22: ...22 Expert Power Control 1100 1101 Declarations of conformity...

Page 23: ...Expert Power Control 1100 1101 2012 Gude Analog und Digitalsysteme GmbH 06 08 2012...

Reviews: