interrupted automatically by action of the thermal sw itch. If
that happens, it is recommended to disconnect the
compressor and let it cool dow n for approximately 5 minutes.
If the compressor does not start up again for some period of
w ork, let it cool dow n for 3 minutes more.
•
Pressure Sw itch:
The compressor has an automatic pressure sw itch fitted to
sw itch the compressor off w hen the upper operating pressure
is reached and it sw itches it on again w hen the air is
demanded. Sw itching pressure 1,7 bar, max. pressure 4 bar.
•
Water Blow Valve
It is possible to control the flow rate using the filter/w ater
separator w ith the control knob and thus the w orking pressure
(w orking pressure /airbrush ca 1-2 bar)! At the same time,
moisture is taken from the pressure air through the silicon
filter pass to be collected in a glass container. The latter
should be emptied regularly (every w eek) subject to the
amount collected using the drain screw .