Fault
Cause
Remedy
A
Compressor does not start
after switching on
Pressure in the air receiver is higher than switch-
on pressure
Release the pressure from the air receiver so
that the pressure switch switches automatically
Faulty feeding
Have the power feeding checked by an
authorized person
Circuit breaker of the motor interrupts the power
feed
Faulty pressure switch
Have the pressure switch replaced by an
authorized person
B
Compressor shortly starts or
buzzes at the reach of the
switch-on pressure and then
switches off automatically
Electric cable is longer than permitted or is of too
small cross-section
Check the length and cross-section of
the electric cable
C
Compressor runs without stop
Suction filter is contaminated heavily
Clean or replace the suction filter
Pneumatic tool has too high air consumption
Check the air consumption of the pneumatic
tool; contact authorized reseller
Leak at the compressor
Locate the leak, notify Güde service
Too much condensing water in air receiver
Drain the condensing water
Leaky pneumatic piping
Check the pneumatic piping, seal the leak
Mud-discharge valve is open or missing
Close or insert it
D
In operation the relief valve
under the pressure switch
releases the pressurized air
Leaky relief valve
Clean or replace the relief valve
E
After switch-off pressure is
reached the relief valve under
the pressure switch releases the
pressurized air until the switch-
on pressure is reached
Insert of the non-return valve is leaky or
faulty
Clean or replace the insert of the non-return
valve
Non-return valve is damaged
Replace the non-return valve
F
Compressor switches on
frequently
Too much condensation water in the air
receiver
Drain the condensation water
Compressor is overloaded
G
Safety valve blows off
Pressure in the air receiver is higher than set-up
switch-off pressure
Have the pressure switch readjusted
/replaced by an authorized person (Güde
Service)
Safety valve is faulty
Replace the safety valve or contact Güde
Service
H
Compressor heats too much
Intake air is insufficient
Make sure that sufficient intake and outlet of
the air is guaranteed (minimum distance from
a wall 40 cm)
Cooling ribs at the cylinder (cylinder head) are
dirty
Clean the cooling ribs at the cylinder (cylinder
head)
Too long period of use
Switch off the compressor
I
The oil level rises without oil
being added
Condensation water accumulates in oil
Compressor is overdesigned, notify the Güde
Service
High air humidity
Replace the oil
J
Compressor is overheated and
it switches off
Compressor is overloaded
Notify the Güde Service
Compressor is faulty
Notify the Güde Service
Compressor has under voltage
Notify the Güde Service
Ambient temperature 35°C
Notify the Güde Service
18