background image

20 

 

 After the Installation 

 

 

1. 

Never  permit  children  to  play  with  or  operate  the  garage  door  opener  either  from  the  wall  station  or  the  remote 
controls.  Keep  radio  transmitter  locked  in  the  car.  Misuse  of  the  push  button  or  transmitter  could  result  in  serious 
injury or even death.

 

 

 

2.  Open  the  garage  door  with  the  remote  controls  only  when  the  garage  door  is  fully  visible  to  you  and  clear  of  all 

obstructions. The garage door should be kept in sight until it is completely open or closed and you are certain that the 
garage door opener has shut off. 

 

 

3.  Attempting  to  exit  the  garage  through  the  garage  door  opening,  while  the  door  is  in  motion,  is  a  very  dangerous 

activity that could result in serious injury or even death. 

 

 

4.  Children and pets should always be clear of the door opening while the garage door is in motion. 

 

 

5.  Check the safety reverse mechanism at least once a month to make sure that it will reverse with the minimum amount 

of force

Also check to be sure that the door will reverse within 100 mm of the floor. See page 16. 

 

 

6.  Check the manual operation of your garage door at least every 90 days to be sure that it is operating smoothly and 

does  not  bind  or  stick.  Tighten  all  bolts  on  the  door  and  visually  check  all  hardware  including  springs  for  wear  of 
damage. Caution: If service is needed contact your local garage door service person. 

 

 

7.  Do not decrease the safety reversing sensitivity mechanism to overcome a damaged or poorly operating door. This 

will  adversely  affect  the  operation  of  the  safety  reverse  mechanism,  which  could  result  in  damage  to  the  door, 
personal injury or even death. 

 

 

Caution: 

Never operate the door opener if the reversing mechanism is not functioning properly. 

 
 

8.  Whenever possible, the manual disconnect should only be used when the door is fully closed. Caution: Extreme care 

must be taken whenever the disconnect cord is pulled with the door partially open. Weak or broken springs may allow 
the  door  to  fall  rapidly  resulting  in  property  damage,  personal  injury  or  death.  If  a  broken  spring  is  evident,  contact 
your  local  garage  door  service  person  immediately  before  disconnecting  the  door  from  the  opener.  Never  attempt 
servicing a broken spring. 

 

 

9.  Always disconnect electrical power supply to the opener when performing any maintenance or service to the opener 

or garage door. Failure to do so could result in electrical shock, property damage, personal injury or death. 

 

 

10.  If  any  damage  to  any  mechanical  or  structural  component  of  the  opener  is  observed,  discontinue  use  and  contact 

your local garage door service person immediately. 

Summary of Contents for ACS0

Page 1: ...r for Sectional and One Piece Track Garage Doors up to 2 4M HIGH Installation Instructions and Owner s Manual READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION This Operator Must be installed b...

Page 2: ...ting Time 4 5 minutes Transmitter Frequency 433 MHz Operation Range 50m open field Coding Type Fixed code Battery 12V A23 Alkaline x 1 Operation Features Safety reverse on closing and stop on opening...

Page 3: ...alling Light Bulb 12 Step 10 Installing Wireless Push Button Step 11 Programming Transmitter Codes 12 Tilt Door Installation 13 Operation and Adjustment Instructions 15 Setting the Limits 15 Setting t...

Page 4: ...se the manual release Only to disengage the trolley Do not use the Red Release Cord and Knob to pull door up or down If possible use the Emergency Release only when the door is closed After installing...

Page 5: ...en release is reset the trolley release lever is snapped back to its original position power is restored and Opener is activated 6 Mechanical Door Lock When properly adjusted opener locks door in clos...

Page 6: ...ay in that position If door pulls open or moves downward the spring mechanism is not adjusted properly Contact a qualified garage door service person to make the necessary adjustments 3 When properly...

Page 7: ...er Head w Sprocket Cover Lamp Dome Transmitter and Visor Clip Header Bracket Door Arm Curved Trolley Assembly Trolley Stop Screw Bag Photo eye system Optional Clevis Pin 1 Long Hex Nut 1 6mm 20 Lock N...

Page 8: ...ted in the diagram Figure 7B Now install the connecting link to the trolley release rod as illustrated Figure 7C Note during the assembly the trolley release rod is actually engaged in the trolley It...

Page 9: ...nder tremendous pressure at all times and can cause serious injury or death if disturbed Do not attempt adjustment Step 1 Mounting the front Bracket Sectional Doors and One piece with Track Mark a ver...

Page 10: ...owed the proper clearance before proceeding Step 4 Mount Power Head to Ceiling Since there are many different ceiling designs all possible mounting illustrations cannot be shown Primary concern is to...

Page 11: ...flame seal the cut end with a match or lighter to prevent fraying or unraveling Figure 10C Release Knob Double Overhand Knot Double Overhand Knot Release Instruction Card Note The Emergency Release Me...

Page 12: ...ton Press the Radio Set Button on the opener as shown in figure 11B The courtesy light will stay on for 30 seconds During this 30 second period press the button on the Wireless Wall Button the courtes...

Page 13: ...the centre hole in the bracket Run one of the 6mm nuts on the end of the bolt a few turns This will temporarily hold the rail in place while the back end is swung upward and rested on a step ladder CA...

Page 14: ...determined in STEP 6 it will be necessary to re position the DOWN limit cam so that the outer slide of the carrier stops as close as possible to this point Move the DOWN limit roller assembly on the...

Page 15: ...ener may cause the motor to Overheat and the Thermal Overload Protection System will shut off the Opener Please wait approximately 15 minutes for the Opener to cool down and automatically reset If the...

Page 16: ...justment is set too light the operator will reverse in the down cycle If the up pressure adjustment is set too light the operator will stop in the up cycle Note There are 12 levels increments of up an...

Page 17: ...hoto eye system could enable a Garage Door to Close on People or Property Causing Serious Injury or Death Perform this Test Monthly to Ensure Proper Operation Testing the Photo Eye System Start the do...

Page 18: ...t to the floor when the door is closed 3 The emergency release knob and cord are secured to the emergency release lever on the trolley The knob is located 2M above the floor and requires no more than...

Page 19: ...eceptacle 3 Remove wireless wall button from wall and disconnect wires from the push button activate transmitter If the operator works from transmitter replace push button 4 Disconnect bell wire from...

Page 20: ...ll bolts on the door and visually check all hardware including springs for wear of damage Caution If service is needed contact your local garage door service person 7 Do not decrease the safety revers...

Page 21: ...21 RPM Reader Wheel A 4 Capacitor A 13 Up Limit A 22 RPM Reader Board A 5 Capacitor Mounting Bracket A 14 Limit Actuator Traveler A 23 RPM Reader Board Bracket A 6 Wiring Harness A 15 Down Limit A24 P...

Page 22: ...raight Door Arm B 2 Header Bracket B 7 Trolley Assembly B 12 Curved Door Arm B 3 Pulley Assembly B 8 Chain Tension Assembly B 13 Door Bracket B 4 Tube B 9 Trolley Release Rod B 14 Sprocket Cover B 5 C...

Page 23: ...m the date of purchase or 6 000 cycles whichever occurs first for the electronics and mechanics A cycle means one opening and closing cycle of the door 2 the remote controlled transmitters and accesso...

Page 24: ...insects or any other event beyond the reasonable control of Guardian Automation o Consumer Goods Components such as globes accessories batteries and other consumable parts are not covered by this war...