ANTI-REMOVAL TAMPER (INCLINOMETER)

The sensor is provided with an anti-removal function (that can be activated with 

DIP1

) which 

establishes whether the sensor is moved from the installing position.

This function is activated just when the sensor is in the HORIZONTAL position and afterwards 

it is inclined. In order to activate the removal detection, it is necessary to put the sensor 

horizontally: from now on the anti-removal is activated; if the sensor moves it indicates tamper 

alarm.

POWER-ON

BEFORE POWER THE SENSOR

If the sensor is already powered (or at battery change), before proceed it is necessary to 

disconnect the battery, open the jumper 

J.TMP

 and hold the tamper switch for about 10 

seconds: in this way the circuit will be completely discharged and will be possible to start-up the 

sensor correctly.

G-OP-WPIR-W and U

Power the sensor only after all the wiring is completed.

When the sensor is powered, the LEDs light on is sequence for some seconds: the sensore starts 

the “

Stabilisation period”

The 

Stabilisation period 

takes about 

2 minutes 

(the infrared and microwave LEDa light on 

in case of detection)  

 

At the end of the stabilization time, the sensor is ready for use.

BATTERY 

(ONLY G-OP-WPIR-U

)

Caution, the device works by lithium battery.

Replace the battery exclusively with one of the same type.

Follow the polarity indicated in the instructions.

Dispose of empty batteries following the current regulations, even in case of equipment 

disposal.

In case of leakage, protect your hands with special gloves.

LOW BATTERY

When the battery is low, the sensor the activates the “low battery” output (model -Universal). 

The low battery alert low battery output is activated after three alarm or 

supervision transmissions (if in test, it is sent after each transmission).

Depending on the control panel or receiver model, the alert is visualized on display or LED. 

Note: the low battery alerts will continue until the battery is replaced.

BATTERY REPLACEMENT

When the battery must be replaced:

 

Disconnect the old battery

 

Open the jumper 

J.TMP

 , then press and hold the tamper switch for at least 3 seconds 

(circuit discharge)

 

Connect the new battery (see the par. “Power on”)

Output Cable

(connect to the transmitter)

Transmitter Space

(maximum dimension)

2

3

I

L

Battery

Sensor board

Transmitter

Connector

(connect to 

CN.OUT

)

Low Battery

(yellow wires)

Tamper

(white wires)

Alarm

(red wires)

4

Summary of Contents for G-OP-WPIR-W

Page 1: ...DETECTIONS TO WHICH THE SENSOR IS SUBJECT IF THE SENSOR IS INSTALLED IN HIGH FREQUENCY OF PASSAGE THE BATTERY DURATION WILL DECREASE DRAMATICALLY THE MAX RANGE DEPENDS SIGNIFICANTLY ON ENVIRONMENT TEMPERATURE Power supply 8 14 VDC n 1 lithium battery pack 6 V Absorption Stand by about 8 mA Stand by about 25 µA Alarm about 5 mA Autonomy estimated About 2 years Stabilization Time at power up About 1...

Page 2: ... caused by presence of regular mosquito nets or rollers within the detection area provided that nets are always taut and rollers are fully raised or lowered If these indications are not met increase both the risk of false alarms and the battery consumption for G OP WPIR U clothes hung etc This avoid unwanted detections During adjustment perform as detection tests as necessary to obtain a correct s...

Page 3: ...minutes even without opening the J MODE jumper The automatic exit is also signalled by the sequential turning on of the LEDs If necessary to increase the TEST mode time simply open and close the J MODE jumper The TEST mode is set as default NORMAL mode J MODE OPENED It s the mode the detector MUST be set when in normal working In this mode after last detection and alarm transmission the detector w...

Page 4: ...on period takes about 2 minutes the infrared and microwave LEDa light on in case of detection At the end of the stabilization time the sensor is ready for use BATTERY ONLY G OP WPIR U Caution the device works by lithium battery Replace the battery exclusively with one of the same type Follow the polarity indicated in the instructions Dispose of empty batteries following the current regulations eve...

Reviews: