GUARDEON Security Systems ApS. Vandtårnsvej 100, 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: [email protected]
3
LEARNING/PAIRING (ONLY G-OP-WPIR-R )
AN LEARNING
1. Power on the sensor and wait the end of stabilization.
2. Set DIP-SWITCH and JUMPERs as follows:
DIP1 = ON
Anti-removal tamper excluded
DIP2 = --
ON or OFF
DIP3 = OFF
DIP4 = --
ON or OFF
J.TMP = OPENED
Anti-opening tamper active
J.LED = CLOSED
LEDs active
J.MODE = CLOSED
Test Mode
3. On control panel/receiver: enter in radio zone learning (“learning by tamper” or “AN” mode).
4. Without any detection press and hold the tamper switch until the BLUE LED turns on:
the detector transmits its AN learning radio code (the BLUE LED stay on for about 2
seconds)
verify the control panel/receiver learned the radio code (press again the tamper switch in
case the learning failed)
DETECTION LEARNING
1. Power on the sensor and wait the end of stabilization.
2. Set DIP-SWITCH and JUMPERs as follows:
DIP1 = ON
Anti-removal tamper excluded
DIP2 = --
ON or OFF
DIP3 = OFF
DIP4 = --
ON or OFF
J.TMP = CLOSED
Anti-opening tamper disabled
J.LED = CLOSED
LEDs active
J.MODE = CLOSED
Test Mode
3. On control panel/receiver: enter in radio zone learning (“detection learning”).
4. Make the sensor detect until the BLUE LED lights on:
• the sensors transmits its alarm radio code
• verify the control panel/receiver learned the radio code (make another detection with the
sensor in case the learning failed)
TEST AND NORMAL MODES (ONLY G-OP-WPIR-U )
With
J.MODE
jumper is possible to set the sensor in TEST or NORMAL mode:
TEST mode:
J.MODE
=
CLOSED
The sensor transmits / signals alarm at each detection.
This mode allows the installer a correct tuning of the detector.
To exit from TEST mode and back to NORMAL, open the
J.MODE
jumper: some seconds
after last detection, the sensor signals the exit by sequentially turning on the LEDs (round
trip).
The sensor exit automatically from TEST after about 5 minutes – even without opening
the
J.MODE
jumper. The automatic exit is also signalled by the sequential turning on of
the LEDs.
If necessary to increase the TEST mode time, simply open and close the
J.MODE
jumper
The TEST mode is set as default.
NORMAL mode:
J.MODE
=
OPENED
It’s the mode the detector MUST be set when in normal working.
In this mode – after last detection and alarm transmission – the detector wait for a “quiet
time” before to consider a new intrusion (alarm).
If during this time there is no detection the sensor will back ready to a new detection,
otherwise the quiet time is extended.
The quiet time is about 30 seconds (not changeable).
The NORMAL mode allow a lower consumption and a longer battery life.
G
H
IR2 detection LED
IR2 detection LED
IR1 detection LED
IR1 detection LED
TX / ALARM LED
TX / ALARM LED
MW detection LED
MW detection LED
Battery connector
Battery connector
Infrared head IR2
Infrared head IR2
Infrared head IR1
Infrared head IR1
Microwave MW
Microwave MW
Anti-opening tamper
Anti-opening tamper
J.LED
Closed = LED enabled
Opened = LED disabled
J.LED
Closed = LED enabled
Opened = LED disabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
J.MODE
Closed = Test Mode
Opened = Normal Mode
J.MODE
Closed = Test Mode
Opened = Normal Mode
DIP-1÷4
Sensore settings
DIP-1÷4
Sensor settings
OUTPUTS CONNECTOR
(for provided cable)
DIP-SWITCH
OFF
ON
DIP1
Anti-removal
Active
Excluded
DIP2
Detection type
Window (low sensitivity)
Door (high sensitivity)
DIP3
Radio test
Normal working
Transmission Test
DIP4
Supervision
OFF
ON
DIP-SWITCH
OFF
ON
DIP1
Anti-removal
Active
Excluded
DIP2
Detection type
Window (low sensitivity)
Door (high sensitivity)
DIP3
Not used
Leave OFF
DIP4
Not used
Leave OFF
1
It is recommended to disable the LEDs (J.LED = OPENED) after the test to increase the
battery life.
It is recommended to disable the LEDs (J.LED = OPENED) after the test to increase the
battery life.
G-OP-WPIR-W
works only in TEST mode.
G-OP-WPIR-R
G-OP-WPIR-U (universal)
G-OP
-WPIR-R - NO
T AV
ALIAB
EL IN DENMARK
G-OP
-WPIR-R - NO
T AV
ALIAB
EL IN DENMARK