Push the cables through the cable gland until
it breaks: in this way the sheath will open just
where necessary, bonding to the cables and
ensuring a higher protection.
PRECAUTIONS
Detector must be installed protected from the elements. Install protected from direct rain.
This sensor has been designed to guarantee a very high immunity to light interference;
however, a very bright light can produce a range decrease.
It is recommended to pay attention during the installation and avoid, as much as possible,
sensitive elements.
puddles, wet roads, smooth concrete surfaces, paved roads.
Infrared detector is sensitive to the “amount of heat” produced by a moving body.
The maximum range of the sensor (measured in meters) is referred to a human body.
However the same “amount of heat” may be produced by a smaller body at lower
distances, or by a larger one at greater distances. It should be considered therefore that
the range of any passive infrared sensor is a RELATIVE measure (referring to a human
body) and NOT ABSOLUTE.
The sensor is highly immune to false alarms caused by presence of regular mosquito nets
or rollers within the detection area, provided that nets are always taut and rollers are fully
raised or lowered. If these indications are not met, increase both the risk of false alarms
and the battery consumption for G-OP-WPIR-U.
clothes hung, etc. This avoid unwanted detections.
During adjustment, perform as detection tests as necessary to obtain a correct sensor
behavior.
The sensor may detect pets (no pet-immune function).
B
C
F
E
D
The detector must be installed only in horizontal position over the opening to protect, oriented
The detector must be installed with the side that presents the LEDs towards OUTSIDE (garden,
backyard, balcony…) and the opposite side towards INSIDE (door or window) to protect:
LED side: towards outside
If the anti-opening tamper is active, the sensor transmits alarm.
INSTALLATION (PLACEMENT)
It is recommended to disable the LEDs (J.LED = OPENED) after the test.
YES
NO
1
YES
NO
2
IR2 detection LED
IR1 detection LED
TX / ALARM LED
MW detection LED
Terminals
Infrared head IR2
Infrared head IR1
Fixing screw
Fixing screw
Cable gland (model -W)
Microwave MW
Anti-opening tamper
J.LED
Closed = LED enabled
Opened = LED disabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
DIP-1÷2
Sensor settings
DIP-SWITCH
OFF
ON
DIP1
Anti-removal
Active
Excluded
DIP2
Detection type
Window (low sensitivity)
Door (high sensitivity)
Range
G-OP-WPIR-W (wired)