19
Certifications
• Emergency exit devices to EN 179:
B 1956:
1
2
A
B
B
D
377B134
B 1959:
1
2
A
BA
377B134
• Panic exit devices to EN 1125:
B 1956:
1
2
A
BB
377B132
B 1959:
1
2
A
BA
377B132
• Fire and smoke protection EN 1634 + DIN 18250 + DIN 4102-
T5+T18
•
•
DO 9.1
•
B 1956:
G107015
M107307
Z107001
•
B 1959
:
G107015
Z107001
2.2 Scope of delivery
Motor-driven lock:
B 1956
1-leaf
B
1959
2-leaf
/
active
leaf
Connecting cable:
B 5490 0300
LiYY 14 x 0.14 mm2, length 10 m
Installation instructions:
C59 803 000
Accessories bag:
C19 930 050
Fixing material
C19 930 000
(only with U-faceplate)
2.3 Accessories
Cable duct:
9-41491-00-0-0
Concealed; for narrow stile profiles
Emergency power supply: B 5490 0301
with B 1956:
Striker
B 9000 1046
24 x 3 x 270 mm; flat striker
9-43501-01-0-8
24 x 3 x 120 mm; flat striker
6-33616-01-0-8
24 x 6 x 120 mm; U-striker
6-33617-01-0-8
24 x 8 x 120 mm; U-striker
with B 1959:
Shoot-bolt lock
B-19900
3.
Functions and Application
3.1 Automatically-locking latchbolt
The latchbolt automatically locks the door by actuating the trigger lever once it has engaged in the
striker (providing motor-driven daytime release has not been activated).
3.2 Panic function E
The lock is only available as escape door lock with panic function E. It must be mounted in the
escape direction with continuous fitting. Only one fixed knob or push/pull handle is permitted on
the other side.