3.
Protection against manipulation
Your system consists of 2 electronic devices:
Fingerprint scanner
SECURE
connect
200 (control unit)
The fingerprint scanner is generally assembled externally (on the outside
of the door). To prevent unauthorised access, your system is equipped with
numerous security functions:
The fingerprint scanner is connected to the control unit using a data
cable. Data transmission is encrypted.
Recording of the user finger and the modification of the system content
is only possible if master finger has already been recognised by the
system.
The fingerprint scanner and control unit are clearly paired for initial
commissioning (pairing).
In order to exchange a component of the door system (SECURE
connect
200R
, SECUREconnect
200F
or fingerprint scanner), you have to start a
re-pairing procedure. To do so, close the reset contact on the board of the
SECURE
connect 200F
or SECURE
connect 200R
for a minimum of 3 seconds
with the power supply connected. We recommend to use an alligator clip.
The terminal can be removed. The pairing process for the SECURE
connect
200R,
SECURE
connect 200F
and fingerprint scanner now restarts. The
fingerprint scanner is reset to the factory setting.