0
• Low friction screw drive (linear actuator) rated for -5 ºF to +60 ºF (-2 ºC to +7 ºC). Use of heater bands on arm and
control box will enhance performance in extreme cold temperatures.
• Powered by a 2 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm.
• Maximum opening arc of 0º. Approximate opening time (90º): From 5 seconds, depending on weight of gate.
• Generates 330 ft lbs of torque at 2v.
POWER
• The system is powered by a 2 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 20 Vac, 8 Vac output transformer rectified to 4.5 Vdc (40 VA) through the GTO
control board. Blade-style control board fuse is rated for 5 A.
NOTE: The transformer should not be
directly
connected to any battery. Do not replace fuses
with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
• Battery charge is maintained by
GTO Solar Panel Charger: float voltage of 4.5 Vdc output from solar panel. A gated
diode on the control board prevents battery discharge.
CONTROL
•
GTO
microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be
adjusted to accommodate an optional kit for push-to-open gates (
see Accessory Catalog
).
• Control board has temperature compensated circuits.
• A circuit on the control board regulates charging. "Sleep draw" is 5 mA; "active draw" is 2 to 5 A.
• Auto-memorization of digital transmitter code.
•
GTO remote-mounted RF receiver tuned to 38 MHz.
• Operator length with push-pull tube fully retracted is 33¾", mounting point to mounting point. Max stroke is 3".
• Adjustable auto-close timer (OFF to 20 s), and obstruction sensitivity.
• Power terminal bock accommodates a transformer and solar panels.
• DIP switches simplify setup of gate operator.
• Accessory terminal block fully compatible with push button controls, digital keypads, safety loops, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO® 2000XL Auto-
matic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and
condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications
listed on
page 19
or call
(800) 543-1236
or
(850) 575-4144
for more information.
* An operation cycle is one full opening and closing of the gate.
GTO/PRO® 2000XL AUTOMATIC GATE OPERATOR
Technical Specifications
These specifications are subject to change without notice.
Number of Cycles Per Day
GTO/PRO 2000XL Gate Capacity /Cycle Chart
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
Gate W
eight
Gate Length
400 lbs.
300 lbs.
200 lbs.
150 lbs.
100 lbs.
50 lbs.
145
155
165
175
185
5’ - 6’
135
125
115
105
135
145
155
165
175
8’
125
135
145
155
165
10’
115
125
135
145
155
12’
DRIVE