- 8 -
STI 1916 CT
3
a
ssembly
3.1 d
eviCe
overview
sw
rt
ge
8
9 10 11
12
14 15 16
13
14 15 16
13
17
19
7
6
4
3
1
20
20
5
1
9
8
16
18
1
9
8
16
5
1
MPTS input lines 1-16
3
Reset IP address and password*
4
Alarm tone off
5
Status LEDs of lines 1…16**
6
Fan access
7
LAN socket for configuration
8
Power ON/OFF
9
GND fan connectors
10
Fan monitoring connectors
11
+12 V fan connectors
12
Fan screws
13
PSU releases
14
PSU brackets
15
IEC connectors C14; connectors for mains cables
16
PSU status LEDs***
17
Connector for potential equalisation
18
RF output
19
Test output –25dB
20
Mounting support
*
Reset IP address/password to 192.168.0.120/geheim (hold depressed for more than 5
seconds)
**
Green = good signal; rot = no signal; red/green blinking; off = modulator off
*** Power off + no fault –> LED
16
blinks green
Power on + no fault –> LED
16
lights green
Power on + fault –> LED
16
blinks red