background image

Grundig SAT S

y

st

E

ms

GSS 
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg

Phone: 

+49 (0) 911 / 703 8877

Fax: 

+49 (0) 911 / 703 9210

E-mail: [email protected]
Internet: http://www.gss.de

Assembly Instructions

Assembly Instructions

English

A

A

CLASS

CLASS

KLASSEKLASSE

HDMT 1000 MPTS

Head-End DVB-T Converter to IP

DVB-T to MPTS

Summary of Contents for HDMT 1000 MPTS

Page 1: ...Strasse 43 D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 E mail info gss de Internet http www gss de Assembly Instructions Assembly Instructions English A A CLASS CLASS KLASSE KLASSE HDMT 1000 MPTS Head End DVB T Converter to IP DVB T to MPTS ...

Page 2: ...the cassette 13 3 5 Updating the software 13 3 6 Retrofitting a CA module 14 4 The control panel at a glance 15 4 1 Menu items 15 4 2 Control panel 15 5 Programming 16 5 1 Programming procedure 16 5 1 1 Channel strips A without CA module and B 16 5 1 2 Channel strip A with CA module 19 5 2 Programming the cassette 20 Selecting the cassette displaying the software version 20 Setting the Ethernet pa...

Page 3: ...etting the hierarchical modulation 32 Setting the station filter 33 Displaying the output data rate 37 Network Information Table NIT 37 Network operator identification 38 Deleting a PID 39 Renaming a PID 39 Saving settings 40 5 2 1 Operation with a CA module 40 Setting the operating voltage for the CA module 40 Setting the PID monitoring 41 Configuring the CA module 42 Decoding services 43 6 Final...

Page 4: ... or inappropriate handling Observe the relevant standards regulations and guidelines on the instal lation and operation of antenna systems Earth the receiving system in accordance with DIN EN 50083 1 60728 11 and VDE 0855 earthing equipotential bonding rail Test the software versions of the head end station and the cassette and update them if necessary The current software versions can be found at...

Page 5: ...g EU directives 2006 95 EC 2004 108 EC The product fulfils the guidelines and standards for CE labelling HF input Channels C05 C12 C21 C69 Frequency range 177 5 226 5 474 858 MHz Input level 60 dBµV 80 dBµV Return loss 8 dB Impedance 75 Ω Symbol rate acc to EN 300744 LAN interface Standard 100 BASE T Data rate 80 MBit Protocols UDP User Data Protocol RTP Real Time Transport Protocol ASI interfaces...

Page 6: ...nes COFDM modulated services programmes and transport streams supplied via the ASI interface into two transport streams in the TPS module according to chapter 2 4 1 The trans port streams are emitted equipped with IP addresses via the LAN interface Principle signal path For operating the cassette in a LAN network it can be assigned its own IP ad dress The cassette has two HF inputs and one LAN int...

Page 7: ...rip B TS B and of the ASI input TS ASI generate the transport stream 2 2 4 1 2 Menu setting A B ASI 1 ASI 2 The transport streams of the receiving stages of channel strips A TS A B TS B and of the ASI input TS ASI generate the transport stream 1 The TS ASI transport stream fed via the ASI input generates the transport stream 2 Transport stream 1 Transport stream 2 ASI input Empfangsteil A Receivin...

Page 8: ...etting 1 ASI ASI MA The transport stream 1 is made available via the ASI output The transport stream 2 channel strip B and the transport stream fed via the ASI input channel strip A MA are provided at the LAN interface equipped with IP addresses ASI input ASI output TS ASI Transport stream 1 Transport stream 2 LAN interface Channel strip A OUT IP Channel strip B OUT IP ASI output LAN interface ASI...

Page 9: ...tion control unit Two LEDs in the channel strips provide an indication with their colour whether an HF signal is present or not The LEDs for the LAN interface show whether a network connection exists and whether a data transfer is in progress When the head end station is switched on the two line LC display shows the software version of the control unit To operate this cassette the software version...

Page 10: ...software version of the con trol unit manually Press any two keys on the control unit of the head end station simultaneously until the display goes dark and the software version e g V 40 appears Cassette After activating the cassette the software version of the cassette is displayed s page 20 ...

Page 11: ...d and the HF output collector Fasten the cassette with the screws 1 3 2 EMC regulations To comply with the current EMC regulations it is necessary to connect the lines leading in and out of the head end station using cable terminals When mounting the cassette in a head end station which is installed in a 19 cabinet make sure the connections leading in and out for the 19 cabi net are made using cab...

Page 12: ...is made between the housing 19 cabinet and cable terminals 3 3 Overview of the cassette 1 HF input channel strip B 2 Status LED of the channel strip B 3 Loop through output of HF input 1 4 HF input channel strip A 5 Status LED of the channel strip A 6 Loop through output of HF input 4 7 Status LED of the LAN interface yellow LED data transfer 8 LAN socket 9 Status LED of the LAN interface green LE...

Page 13: ... a PC or a notebook and the BE Flash software to update the software of the cassette You can find the BE Flash software and the current operating software of the cassette at the website www gss de Use a one to one cable to connect the cassette s RS 232 interface and the PC according to the wiring scheme below If necessary use a standard RS 232 USB adapter Start the BE Flash software and update the...

Page 14: ...ing several services The hardware and software of this cassette have been thoroughly pre pared and tested Any changes made by service providers in the data structures might im pair or even prevent this function When working with the CA module please read the corresponding op erating manual from the respective provider Insert the smart card 1 into the CA module 2 so that the chip 3 on the smart car...

Page 15: ...sion protocol port number Number of data packets forward error correction transmission channel Output IP address Input channel Hierarchical modulation Station filter CA module if available Output data rate Network Information Table NIT Network operator identification Deleting a PID Renaming a PID 4 2 Control panel The key pad on the head end station is used to scroll through the menus step by step...

Page 16: ...te please wait V 40 Box 4 V 10 DVBT MPTS Box 1 Box 5 t 10 s Bx 4 stat ETHERNET Options stat DHCP A Bx 4 192 168 0 1 IP GATEWAY Bx 4 255 255 255 0 IP MASK Å Ï Bx 4 192 168 0 128 IP ADDR Å Ï Å Ï Bx 4 60000 UDP PORT Å Ï Å 0 65535 Ein On Bx 4 A B ASI 1 INROUTE ASI 2 A ASI 1 B ASI 2 A B ASI 1 ASI 2 page 18 ...

Page 17: ...ont ASI OPTION Å Ï Å Ï Bx 4A on UDP MODE PORT 1234 ASI ASI 1 ASI ASI MA 2 ASI ASI MB Bx 4A 7 off PKTS FEC Å Ï on off UDP RTP 0 65535 Å Ï off 10 9 20 19 Annex A Annex B 1 7 Bx 4A 227 40 50 60 OUT IP Å Ï Bx 4A C30 546 0 INPUT OK Å Ï Frequenzanzeige Feinabstimmung Frequency display Fine tuning C5 C12 C21 C69 64 64 Bx 4A Priority high INPUT high low Å Ï page 18 ...

Page 18: ... on off Å Ï on off Å Ï Services entfernen hinzufügen Removing activating services nächster Service next service Å Ï Services entfernen hinzufügen Removing activating services nächster Service next service Å Ï 01 07 Bx 4A TV Das Erste Bx 4A Filter PROGRAM on 01 09 Bx 4B TV ZDF ASI Å Å Bx 4A 51400 kbps DATARATE C D Kanalzug A mit CA Modul Channel strip A with CA module Kanalzug A ohne CA Modul Kanal...

Page 19: ...en CA Modul The information displayed is dependent on the CA module used Bx 4A 01 03 Information MENU Bx 4A TV X 04 09 S X entschlüsselt decrypted 0 verschlüsselt encrypted X 0 nächster Service next service Bx 4A PID Check CA on Å Ï on off M Å Ï D Bx 4A Menu CA Edit Bx 4A Supply CA 5 0 V 3 3 V 5 0 V C page 18 page 18 ...

Page 20: ...m Using the AUDIO button previous menus can be activated Switch on the head end station The display shows the software version of the head end station e g V 40 The processor reads the cassettes data approx 10 seconds Selecting the cassette displaying the software version Select the cassette you want to program e g Box 4 by repeatedly pressing the button if necessary The display shows e g the menu ...

Page 21: ...et parameters Press the button to activate the setting options Options The Setting the IP address of the cassette menu IP ADDR is activated Setting the IP address of the cassette If you choose to enter the Ethernet parameters manually set the IP address of the cassette in this menu If DHCP is selected the IP ADDR IP MASK and IP GATEWAY sub menus display the parameters that were assigned auto matic...

Page 22: ...this menu you define the address range for the cassettes connected to the LAN network Use the buttons to place the cursor under the digit of the IP address displayed to be set and use to set the IP address wished Press the button The Setting the address of the gateway IP GATEWAY menu is activated Bx 4 stat ETHERNET Options stat DHCP Bx 4 192 168 0 128 IP ADDR Å Ï Å Bx 4 stat ETHERNET Options stat ...

Page 23: ...s activated Setting the UDP port The UDP port setting is required if the cassette needs to be reached externally to make the setting such as from another input frequency This setting is intended for future functions and can be skipped for this cassette Use the buttons to place the cursor under the digit of the port number displayed to be set and use to set the port number wished 0 65535 Press the ...

Page 24: ...lecting the output signal path OUTROUTE menu is activated Selecting the output signal path In this menu you define the signal path of the output transport streams Menu setting ASI ASI s chap 2 4 2 1 page 8 Menu setting 1 ASI ASI MA s chap 2 4 2 2 page 8 Menu setting 2 ASI ASI MB s chap 2 4 2 3 page 9 Bx 4 A B ASI 1 INROUTE ASI 2 A ASI 1 B ASI 2 A B ASI 1 ASI 2 Bx 4 1 ASI OUTROUTE ASI MA Bx 4 10800...

Page 25: ...or the ASI component connected For this setting please take the required information from the documentation technical data of the ASI component to be connected Use the buttons to place the cursor under the digits to be set for the transfer rate then use the buttons to set the transfer rate wished Press the button The Setting the ASI options ASI OPTION menu is activated Bx 4 1 ASI OUTROUTE ASI MA B...

Page 26: ...tons to place the cursor un der pos positive standard and using the but tons set to neg negative To change the type of transmission press the buttons to position the cursor under cont continuous standard and using the set to burst Setting cont The data packets of the user data are collected to a great data packet in the transport stream Setting burst The data packets of the user data are spaced ou...

Page 27: ...ivated Switching the IP address off or on Selecting the transmission protocol Setting the port number In this menu you can switch off or on the output IP address of the channel strip and define the transmission protocol and the port number Switching the IP address off or on Press the buttons to switch off or on the output IP address of the channel strip Bx 4 Line A LINE Line B Line A Line B B Å Ï ...

Page 28: ...t Protocol is for continu ously transmitting multimedia data streams in an IP network Unlike UDP the header is transmitted which makes the data transmission more robust Setting the port number Press the button to position the cursor under the port number e g 1234 Use the buttons to position the cursor under the digit of the port number displayed to be set Using the buttons set the port number wish...

Page 29: ...a packets Using the buttons define the quantity of MPEG data packets in one IP data packet 1 7 Setting the forward error correction Press the button to position the cursor under off In position off the forward error correction FEC is switched off Using the buttons set the value of the FEC wished off 10 9 20 19 Setting the transmission channel Press the button to position the cursor under Annex Use...

Page 30: ...nel INPUT menu is activated Setting the input channel Once the HF receiving stage has synchronised to the input signal OK is displayed If appears in the second line of the display there is no input signal present Check the configuration of the antenna system and the head end station as well as the preceding settings of the cassette Use the buttons to set the desired input channel C5 C12 C21 C69 Be...

Page 31: ... In addition to the indicator in the display there is also a status LED which indicates whether a transport stream is received or not LED indicator Indication Green Signal available Red No signal Press the button The menu Setting the hierarchical modulation INPUT Priority is activated Bx 4A C30 0 INPUT OK 64 64 Status LED Channel strip B Status LED Channel strip A ...

Page 32: ...receive both data streams in poorer reception conditions only the HP portion By pressing set to high or low Not relevant in the case of standard modulation If the input signal path A B ASI 1 ASI 2 is selected the station filter of channel strip B is used in the channel strip A Therefore perform the settings for channel strip B according to the pages 30 32 Setting the input channel Setting the hier...

Page 33: ...ming procedure shown below corresponds to the setting A B ASI 1 ASI 2 With this setting the transport stream of channel strip B is routed to the transport stream of channel strip A and there fore cannot be set in channel strip B Programming channel strip B the transport stream coming from the ASI input can be processed only INROUTE menu setting A B ASI 1 ASI 2 Channel strip A Bx 4A Filter PROGRAM ...

Page 34: ...el strip A e g Bx 4A TV 01 07 Das Erste Meaning of the indicators in the example Bx 4A Slot 4 channel strip A TV Television type of service The currently selected service is activated 01 07 The 1st of 7 services is being displayed Das Erste Name of the service Further possible terms displayed RA Radio type of service For radio stations the screen of the connected TV or test receiver is darkened Th...

Page 35: ... in the same way as channel strip A To save changes and to activate the station filter press the button The filter is activated The display shows PROGRAM Filter on If services are activated the corresponding PIDs au dio video text are inserted into the transport stream and the PAT and SDT tables are updated Test the status of the individual services If the filter is switched on press the button In...

Page 36: ...ss the button The Displaying the output data rate DATARATE menu is activated when the channel strips A without a CA module installed and B are programmed Programming the channel strip A with a CA mod ule installed the Setting the operating voltage for the CA module CA Supply menu is activated page 40 Bx 4A Filter PROGRAM off Å Å 01 07 Bx 4A TV Das Erste Å Ï ASI Å Ï on off PROGRAM on Bx 4A Filter ...

Page 37: ...rk Information Table NIT This menu has no function at this cassette Therefore it can be skipped Press the button The Network operator identification CAT ID menu is activated Bx 4A 51400 kbps DATARATE C D Kanalzug A mit CA Modul Channel strip A with CA module Kanalzug A ohne CA Modul Kanalzug B Channel strip A without CA module Channel strip B Bx 4A off NIT Make ...

Page 38: ...set the operator ID to 2 Use the buttons to position the cursor under the digit to be set Use to change the operator ID from 0xDE00 to 0xDE02 Use the button to position the cursor under off then use to activate the new CAT on The menu display switches to modified If you try to change the network operator identifica tion operator ID of a transponder which cannot be modified not modified appears in ...

Page 39: ... Renaming a PID In this menu you can allocate a new address to a PID retain ing the complete data content Use the buttons to place the cursor under the re spective digit of the hexadecimal number of the PID to be changed 0x0000 and set the hexadecimal number us ing Use the buttons to place the cursor under the re spective digit of the hexadecimal number of the new PID 0000 Set the hexadecimal numb...

Page 40: ...ed data page 27 If necessary set channel strip B 5 2 1 Operation with a CA module In order for this function of the CA module to be possible in the Setting the station filter PROGRAM menu page 33 services must be selected which can be decoded by the CA module you are using and your smart card Where both encrypted and unencrypted services are trans mitted short term picture loss may occur when swit...

Page 41: ...s switched on If particular PIDs are not decrypted the CI module is reset Additionally dropouts may occur if several services are de crypted To prevent this the PID monitoring can be switched off Use the buttons to switch off or on the PID moni toring Press the button The Configuring the CA module CA menu is acti vated Bx 4A PID Check CA on on off ...

Page 42: ...NU menu of the CA module The display shows e g Bx 4A 01 03 MENU Information Meaning of the indicators Bx 4A Slot 4 channel strip A 01 03 The first of three menu items is activated MENU The menu of the CA module is activated For the explanation of further details please use the operat ing instructions of the CA module used Bx 4A Menu CA Edit Die angezeigte Information ist abhängig vom verwendeten C...

Page 43: ...vated Decoding services In this menu you select the services wished from the encoded input transport stream which are to be decoded The display shows e g Bx 4A TV X 04 09 Meaning of the indicators in the example Bx 4A Slot 4 channel strip Tuner A TV Television type of the service X The currently selected service is decrypted 04 09 The 4th of 9 services read is being displayed Name of the service B...

Page 44: ...e CA menu Press the button The Displaying the output data rate DATARATE menu page 37 is displayed Set channel strip B if necessary 6 Final procedures After installing the head end station upgrading accessories or installing cassettes it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Securely tight...

Page 45: ... 45 45 ...

Page 46: ...Alterations reserved Technical data E O E GSS GmbH 03102009 Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 Email service gss de ...