- 42 -
HDE 400
asi i
nPut
station
filter
; b
yPass
asi => rf
Herein you get access to the submenus for ASI input filter settings.
—> If no ASI input filter settings should be done, press button
.
The "Output data rate" – "
DATARATE
" main menu is activated (page 44)
Bx 2
ASI
INPUT
OK =>
—> If no ASI input signal is present, "– –" is displayed instead of "OK".
Bx 2
ASI
INPUT
– – =>
• Press the button.
Bx 2
all
FILTER
Using buttons
you can select, whether all services (
"all"
) or only se-
lected services (
"manual"
) are passed through.
The selection
"all => RF"
activates a bypass (page 9), which passes all services
from the ASI input directly to the modulator.
—> The encoded input signal of the video/audio sockets will then be
output only via the ASI output and the LAN socket, can processed
externally (e.g. scrambled) and via the ASI input forwarded to the
modulator.
• Activate the filter function by selecting "
manual
".
• Press the
button.
—> All services from the ASI input will be read, and then displayed with
name and type of the service..
—> If no services is found, the following message will appear in the
display: "
no Service
". In this case, check previously adjusted settings
for the cassette and the components connected to the ASI input.