Autoflow Operation
34
After the
Dump Cycle
, the unit returns to
the beginning of th
e Dry Cycle
, the
Fill system(s)
refill the
Drying Chamber
and the process begins
again. If the
Dry Timer
reaches zero after the
grain temperature reaches the
Grain Temperature
Setpoint
on the
Moisture Control Thermostat
the
unit does not enter
Temperature Hold.
It goes
right to the
Dump Cycle.
The unit continues with the same operation
until either no grain is present against the
Wet
Supply Rotary Switch,
or the
Storage Chamber
becomes full.
If the
Wet Storage Tank
becomes empty
while the fill systems are running, the
Unload
Delay
starts to count down. When the
Unload
Delay
reaches zero the fill system(s) shut off
along with the dryer and a
Wet Supply Hopper
Empty
error is displayed on the
Dryer Control
Panel
screen. If there is grain against the
Drying
Chamber Low Level Rotary Switch
the unit can be
restarted by pressing the start switch. When the
start switch is pressed the screen on the
Dryer
Control Panel
will read Press Enter to Dry
Remaining Grain. If the enter button is pushed
the dryer will restart without running the fill
system(s). The dryer will remain running until the
completion of the next
Dump Cycle
, after which an
out of Grain error is displayed on the
Dryer
Control Panel
and the dryer stops.
If the
Storage Chamber High-Limit Rotary
Switch
becomes covered with grain during the
Dump Cycle
the dryer will continue through the
Dump Cycle
and will continue to the next
Dry
Cycle
. When the
Dry Cycle
is complete the unit
will not continue to the
Dump Cycle.
A Storage
Chamber Full error will be displayed on the
screen and the dryer will stop. The unit will not
dump automatically until grain has been removed
from the
Storage Chamber
.
If the dryer stops for any reason the
Aera-
tion Fan Bypass
switch is placed in the
continuos position. The
Aeration Fan Bypass
switch is located in the side of the
Fill System
Control Box
. If the
Aeration Fan Bypass
switch is
placed in the automatic position the
Aeration
Fan
stops whenever the dryer stops.
Items In Italics Are Defined In the
Dryer Terminology Section.
THEORY OF OPERATION
Top Dry Autobatch
Theory of Operation
Control Panel Switches Status:
Control Power:
On
24v Power:
On
Moisture Control Thermostat:
On
Aeration Fan:
Auto
Load Auger:
Auto
Fan:
Auto
Heater:
Auto
Dump:
Auto
Dry & Hold:
Off
Emergency Stop Switches Status
Autoflow Control Box Emergency Stop: pulled out
Fill System Control Box Emergency Stop: pulled out
Actuator Control Box Emergency Stop: pulled out
Aeration Fan Bypass:
Continuos
continued on page 35
Summary of Contents for PNEG-728
Page 1: ...1 Autoflow Operation 1 Autoflow Operation PNEG 728 ...
Page 2: ...Autoflow Operation 2 This page was left blank intentionally ...
Page 6: ...Autoflow Operation 6 DECAL PLACEMENT ...
Page 10: ...Autoflow Operation 10 CONTROL SYSTEM Electronic Monitoring Control System ...
Page 13: ...13 Autoflow Operation CONTROL PANEL ...
Page 14: ...Autoflow Operation 14 CONTROL SYSTEM Electronic Monitoring Control System ...
Page 19: ...19 Autoflow Operation CONTROL SYSTEM ...
Page 20: ...Autoflow Operation 20 CONTROL SYSTEM ...
Page 21: ...21 Autoflow Operation CONTROL SYSTEM ...
Page 22: ...Autoflow Operation 22 CONTROL SYSTEM ...
Page 28: ...Autoflow Operation 28 FILL SYSTEM CONTROL BOX ...