PNEG-1858
12" and 16" “X” Series Sweep
21
4. Start-Up
Perform Pre-Start Checks
1. Make sure ALL shields are in place.
2. Inspect the drive unit for any problems or potential problems.
3. Be aware of any emergency shut down procedures. Two (2) people must always be in position to
monitor the operation of the equipment from outside the bin.
4. Before starting the auger for the first time, make sure that all parts are assembled correctly according
to the instructions in this manual.
5. If an operator present device is used, ensure it is installed and enabled in the controller.
6. Ensure that all thermal protectors are connected or the sweep will not operate.
Start the Auger
1. When running the auger for the first time or the first time of the season, “break-in” the auger by
running the auger at partial capacity until it is “polished smooth” before attempting full capacity.
DANGER
To ensure that the drive is not unexpectedly started, turn OFF and lock out the
power source before proceeding.
Failure to perform any or all of these pre-start checks may cause damage to the
equipment and/or cause SERIOUS INJURY or DEATH to those in the work area.
Failure to perform any or all of these pre-start checks may also be a misuse of
the equipment. Any misuse of the equipment may void the warranty.
WARNING
ALWAYS keep ALL guards and shields in place, until all the power is
disconnected and locked out.
WARNING
Make certain ONLY trained operators are in the work area before operating or
moving the machine. Two (2) people must always be in position to monitor the
operation of the equipment from outside the bin.
CAUTION
DO NOT start or stop the auger while it is under load.
CAUTION
Failures may occur if the auger is run full before it has been “polished” during
the “break-in” period.
CAUTION
NEVER operate the auger empty. Operating augers empty for any length of
time will cause excessive wear. NEVER operate the auger at speeds higher
than recommended.
CAUTION
Be aware of any unusual vibration or noises during the initial start-up and
“break-in” period. If anything unusual is detected, immediately shut down the
auger and disconnect and lock out the power supply before servicing.
Summary of Contents for X Series Sweep
Page 1: ...PNEG 1858 12 and 16 X Series Sweep Operator s Manual PNEG 1858 Date 11 27 12 ...
Page 40: ...8 Control Panel Diagrams 40 PNEG 1858 12 and 16 X Series Sweep Control Panel Schematic 600V ...
Page 48: ...48 PNEG 1858 12 and 16 X Series Sweep NOTES ...
Page 50: ...10 Parts List 50 PNEG 1858 12 and 16 X Series Sweep Main Auger Components ...
Page 52: ...10 Parts List 52 PNEG 1858 12 and 16 X Series Sweep Main Auger Components Continued ...
Page 56: ...10 Parts List 56 PNEG 1858 12 and 16 X Series Sweep Track Drive Components ...
Page 60: ...10 Parts List 60 PNEG 1858 12 and 16 X Series Sweep 16 Flight Connection Components ...
Page 62: ...10 Parts List 62 PNEG 1858 12 and 16 X Series Sweep Wheel and Caster Components ...
Page 64: ...10 Parts List 64 PNEG 1858 12 and 16 X Series Sweep 12 and 16 Plow Components ...
Page 72: ...10 Parts List 72 PNEG 1858 12 and 16 X Series Sweep Control Panel Assembly 380V 3 Phase ...
Page 74: ...10 Parts List 74 PNEG 1858 12 and 16 X Series Sweep Control Panel Assembly 480V 3 Phase ...
Page 76: ...10 Parts List 76 PNEG 1858 12 and 16 X Series Sweep Control Panel Assembly 600V 3 Phase ...