Hexylon High-performance portable meter
36
6.4.5.- Spectrum
This feature shows the spectrum of the signal.
6.4.5.1.-Main window
If you tap to enable marks:
Power or C/N
measurement.
Tap to change
Spectrum
parameters
Swipe to tune next/previous channel
Drag to tune any channel
Spread/Pinch to change span
Tap to enable/disable
marks
Drag to move the active mark
Tap to activate a mark
+ adds a new mark (max. 4).
- removes the active mark
Delta: measures the level difference between two marks
6.4.5.2.- Options context menu
• Span: 100KHz, 1MHz, 5MHz, 10 MHz, 20 MHz, 50
MHz, 100 MHz, 200 MHz, 500 MHz, 1.0GHz, 2.0GHz,
3.3GHz, Other.
• Reference level: Auto, 50dBuV – 130dBuV
• dB/div: Auto, 5dBuV, 10dBuV
• RBW: 500 HzW – 5MHzW
• VBW: 100Hz – 1MHz
• Advanced: Access to spectrum advanced features:
-
Hold: enables/disables max. hold y min.
hold features. Tapping on Clear button to
restart hold trace.
-
Trigger: enables/disables the trigger by
level feature. To select the level, tap on
the label and a popup keyboard appears.
-
Fill: enables/disables the spectrum graph
filled.
• Quality profile: allows to select the quality profile
• Powering:
-
VDC: Selects the preamplifier powering.
-
DiSEqC (only satellite band): selects the
DiSEqC parameter (Sat A, Sat B, Sat C, Sat
D)
-
Positioner (only satellite band): makes it
possible to control the DiSEqC motors
used to move mobile parabolic antennas.
This function is available in satellite mode
and when the equipment is powering the
LNB.
Halt: This command stops the motor
movement.
East: Allows to move the motor in the
Summary of Contents for Hexylon
Page 2: ......
Page 69: ...EN 69...
Page 70: ...Hexylon High performance portable meter 70...
Page 72: ......