When PDP is on, the chart looks like this:
6.4.7.2.- Options context menu:
• Min. Level: indicates the level from which the
meter must take the echoes into account.. You can
also change this level by dragging the horizontal
light blue level.
• Zoom: OFF, 2x, 4x, 8x, 16x. You can also Spread/
pinch on the screen.
• Units: us, Km.
• Quality profile: allows to select the quality profile
Enables/
disables
PDP
List of measurements of
the channel
Tap on it to see the
parameters of the signal
The blue mark indicates
the delay and the level of
the signal
Drag to move
Light blue mark indicates
the minimun level of the
echoes
Drag to move
List of echoes
with the delay
and level of
each one
• Powering:
-
VDC: Selects the preamplifier powering.
-
DiSEqC (only satellite band): selects the
DiSEqC parameter (Sat A, Sat B, Sat C, Sat
D)
-
Positioner (only satellite band): makes it
possible to control the DiSEqC motors
used to move mobile parabolic antennas.
This function is available in satellite mode
and when the equipment is powering the
LNB.
Halt: This command stops the motor
movement.
East: Allows to move the motor in the
EAST direction. Each click corresponds to
one step in the movement of the motor
(pitch motors). By holding the key down,
successive movement sequences will be
executed until the key is released.
West: Motor movement in the WEST
direction. Each click corresponds to
one step in the movement of the motor
(pitch motors). By holding the key down,
successive movement sequences will be
executed until the key is released.
Store: 8 storage positions are available
to store at up to 8 antenna positions . This
command allows one of 8 positions to be
chosen where the current position of the
antenna will be stored.
Goto: recovers one of the 8 positions
for the antenna that has been previously
stored
-
SCR (only satellite band): Selects the SCR
parameters (multiswitch, standard and
slots) When a slot is enabled (for example
slot 3, freq. 1210MHz), the meter will tune
into the slof frequency (1210MHz) and
will set the slot with the meter parameters:
frequency, band (powering), and DiSEqC.
In addition, a SCR icon will be shown in the
bar at the top (SCR3) to indicate thar the
slot is enabled. While the slot is enabled,
all the setting changes of the meter, will
be applied to the currently slot (SCR3).
6.4.8.- MER/carrier
This feature represents MER value for each carrier
of the DVB-T signal. This is pretty useful to detect
if there is any interference inside the channel that
Summary of Contents for Hexylon
Page 2: ......
Page 69: ...EN 69...
Page 70: ...Hexylon High performance portable meter 70...
Page 72: ......
Page 73: ...901620_901621_1 23_EN...