5
1.7 Specifications
PERFORMANCE
Full Scale (F.S.)
Selectable 0 to 999,990
Resolution
20-bit A/D converter, 100,000d displayed
±
500,000d internal
A/D Conversion
60 Hz
Zero Track
0d – 10.0d
Operating Temperature
-30
°
C to +65
°
C
Units of Measure
lb, kg, tons
ELECTRICAL
Power Requirement
Input: 10.5 – 16 VDC, minimum 0.8A
Excitation Voltage
10 VDC
Excitation Current
180 mA max. / (4) 350
Ω
bridge
Signal Input Sensitivity
0.1 – 20 mV/V
Signal Connection
4 lead
PROCESS CONTROL
Remote Input
1 momentary contact closure (100ms
minimum)
TARE, PRINT, ZERO, ADVANCE,
PRINT & TARE
COMMUNICATIONS
Serial
RS232 bi-directional port
Data Output
1 of 7 selectable fixed-format
transmissions and custom user defined
format.
Protocol
Selectable
Baud Rate
300 – 19200 baud (Print Port)
1200- 19200 baud (Comm Port)
DISPLAY
LCD
240 x 64 DOTS graphic type Liquid
Crystal Matrix display
.
ENCLOSURE
Stainless Steel
Wash-down enclosure. NEMA 4X TYPE
(IP66)
OPTIONS
Wall Mount Kit
Swivel bracket/stand
Remote Display
2” (51mm) LCD Back-light
Remote RF Key
Wireless remote key functions
Cables
Remote display, comm, printer
Data Logger
Serial recording device
Agridata Program
Windows based interface program