- 33 -
SMCIP 402 C/T
—> GSS Multiswitches must be triggered by the following DiSEqC co-
mands:
Input group A —> DiSEqC command S01
Input group B —> DiSEqC command S02
Input group C —> DiSEqC command S03
Input group D —> DiSEqC command S04
Example: In order to trigger input group B for horizontal polarisa-
tion and high band
S02Hh
must be set.
• Press the
MODE
button.
—> The "Input symbol rate / DVB mode" submenu – "
SYMBOL
" is activated.
i
nPut
symbol
r ate
In this menu you set the symbol rate of the desired transponder in kSymb/s.
SYMBOL
8PSK 2/3
A
22000
The symbol rates of the satellite transponders can be found in the current chan-
nel table of the satellite operator, in various satellite magazines and in the
Internet.
• Using button
MULTI
you can toggle the customary standard values
22000/27500 kSymb/s.
• For deviating values use the buttons
</>
to position the cursor under the
digit to be set for the displayed symbol rate.
• Press the
+/–
buttons to enter the corresponding digit of the desired symbol
rate.
• Repeat the procedure by the quantity of the digits to be set.
—> If an input signal is present, its DVB mode (e.g. 8PSK) and the FEC
factor (e.g. 2/3) is displayed.
• Press the
MODE
button.
—> The "Input frequency" sub menu – "
FREQ
" is activated.