Split-type room air conditioner / Installation Manual
19 / 56 EN
Fig. 5.4
A
Warning
Be extremely careful not to dent or damage the piping while bending them away from
the unit. Any dents in the piping will affect the unit’s performance.
Step 5: Connect drain hose
By default, the drain hose is attached to the lefthand side of unit (when you’re facing the back of the
unit). However, it can also be attached to the right-hand side.
1. To ensure proper drainage, attach the drain hose on the same side that your refrigerant piping exits
the unit.
2. Attach drain hose extension (purchased separately) to the end of drain hose.
3. Wrap the connection point firmly with Teflon tape to ensure a good seal and to prevent leaks.
4. For the portion of the drain hose that will remain indoors, wrap it with foam pipe insulation to
prevent condensation.
5. Remove the air filter and pour a small amount of water into the drain pan to make sure that water
flows from the unit smoothly.
C
Note on drain hose placement
Make sure to arrange the drain hose according to Fig. 5.5.
•
DO NOT kink the drain hose.
•
DO NOT create a water trap.
•
DO NOT put the end of drain hose in water or a container that will collect water.
Plug the unused drain hole
To prevent unwanted leaks you must plug the unused drain hole with the rubber plug provided.
5
Indoor unit installation
Summary of Contents for GIN 090
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 139: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey...
Page 140: ......
Page 167: ...Fabricat de Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turcia...
Page 168: ......