28 / 56 EN
Split-type room air conditioner / Installation Manual
60cm (24in) above
30cm (12in)
on left
200cm (79in)
in front
30cm (12in)
from back wall
60cm (24in)
on right
Fig. 6.1
DO NOT install unit in the following locations:
•
Near an obstacle that will block air inlets and outlets
•
Near a public street, crowded areas, or where noise from the unit will disturb others
•
Near animals or plants that will be harmed by hot air discharge
•
Near any source of combustible gas
•
In a location that is exposed to large amounts of dust
•
In a location exposed to a excessive amounts of salty air
Special considerations for extreme weather
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier
in front of the unit to protect it from extremely heavy winds.
See Fig. 6.2 and Fig. 6.3 below.
6
Outdoor unit installation