9.8. Events
9.8.1. Application (Alarm Settings)
The IP Camera is equipped with one alarm input and one relay output for cooperation with the alarm system to
catch event images. Please refer to the alarm pin definition below to connect alarm devices to the IP Camera if
needed. The alarm configuration page is also shown below.
For details on how to connect the alarm input/output, please refer to the Chapter 4.1. Camera Overview.
Alarm Switch :
The default setting for the Alarm Switch function is <Off>. Enable this function by selecting <On>. Users can also
activate the function according to the schedule previously set in the <Schedule> setting page. Select <By
schedule> and click <Please select…> to choose the desired schedule from the drop-down menu.
Alarm Type :
Select an alarm type, “Normal close” or “Normal open”, that corresponds with the alarm application.
Alarm Output :
Define the alarm output signal as “high” or “low” for the normal alarm output status according to the current
alarm application.
Triggered Action (Multi-option) :
The Administrator can specify alarm actions that will take place when the alarm is triggered. All options are
listed as follows:
- Enable Alarm Output:
Select this item to enable alarm relay output.
- IR Cut Filter:
If you select this item, the camera’s IR cut filter (ICR) will be removed (on) or blocked (off) when the alarm input is
triggered.
NOTE: The IR Function (Refer to IR Function) cannot be set to <Auto> mode when this trigger action is enabled.