Summary of Contents for GCA-C0245P

Page 1: ...GCA C0245P 13 1 15 08 2011 Owner s Manual ASP AG Motorized Dome Cameras GCA C0245P Motorized Dome Day Night Camera 36x Zoom WDR GCA C0345P Motorized Dome Day Night Camera 36x Zoom WDR...

Page 2: ......

Page 3: ...he 360 endless rotation and the 10 190 tilt travel make tracking the object passing directly beneath the dome possible A maximum of 256 preset points can be programmed for precise location of target a...

Page 4: ...to rain or moisture 3 Package Contents These parts are included for GCA C0245P These parts are included for GCA C0345P 4 Installation Do not install the product in a location subject to high temperatu...

Page 5: ...a PC The Swiftdome Cameras contain a built in receiver that decodes commands originating from a control device Connect the Dome Cameras to other devices as shown in the diagram to complete a video sur...

Page 6: ...off from the camera body STEP 3 Remove the protective cover and the PE sheet STEP 4 Attach the dome cover to the camera body Before doing so apply some lubricant on the cover s water proof rubber to m...

Page 7: ...wo sides of it DO NOT press the cover as shown in the figure this might cause damage to the Dome Camera STEP 6 Screw the dome cover and the camera body together STEP 7 Set the switches located at the...

Page 8: ...oth sheets from the dome cover Step 4 Attach the dome cover to the dome body 4 2 Switch Connector Definition Before connecting the Dome Camera to other devices of a CCTV system please complete first t...

Page 9: ...adjustment respectively The switch SW 5 is mainly used when users want to restore the camera to factory default status moreover once a firmware upgrade was carried out users need to reset switch SW 6...

Page 10: ...on 4 6 Cable Connection The Dome Camera is supplied with one integrated 22 pin Data Cable for connecting with the power video and RS 485 audio input audio output cables Please read the following secti...

Page 11: ...hermore when wiring the power cable make sure the Ground wire is inserted into the mid pin of the terminal block 4 6 3 22 Pin Connector Definition With the 22 pin connector installers can simply conne...

Page 12: ...total cable length exceeds 4000 feet using a repeater to maintain the signals is recommended Please refer to the figure and the table below for pin definition and wiring 4 6 5 Cable Wiring and Connect...

Page 13: ...k the terminal press the hook as indicated in the figure with a proper tool and pull it out gently Connect the 22 pin connector to its mating port on the back plate of the Dome Camera NOTE The figure...

Page 14: ...5 Operation and Configuration 5 1 OSD Display Format Regarding information about OSD display position and function description please refer to the table below 12 English...

Page 15: ...D Menu Tree The OSD setup menu structure is listed in the following section The star symbol indicates the factory default For detailed function description please refer to 5 3 Configuration Menu 13 En...

Page 16: ...14 English...

Page 17: ...ed functions and parameter settings of your Swiftdome can be set by the OSD On Screen Display menu with a control device such as a control keyboard The tables below show the parameters that can be set...

Page 18: ...Portuguese Spanish French German Italian Polish Russian Traditional Chinese Simplified Chinese and Turkish You can straight away set a desired language on MAIN PAGE 1 as shown below As you select a la...

Page 19: ...below Normal Mode In this mode the camera will stay focussed automatically and continuously in any condition Zoom Trigger Mode Z TRIG In this mode AF is activated at the time when zoom is changed PTZ...

Page 20: ...in cooperation with the shutter speed to achieve consistent exposure output The shutter speed ranges from 1 10000 to 1 50 IRIS In this mode the IRIS function adjusts exposure in higher property SHUTTE...

Page 21: ...sehold Lighting Colour Temperature 2 500 to 3 000 K 75 watt Bulb Colour Temperature 2 820 K Candle Flame Colour Temperature 1 200 to 1 500 K INDOOR 3200 K Base mode OUTDOOR 5800 K Base mode ATW Mode A...

Page 22: ...TAL NOISE REDUCTION D N R With 2D 3D Noise Reduction the processor analyses pixel by pixel and frame by frame to eliminate environmental noise signals so that the highest quality image can be produced...

Page 23: ...de almost no delay occurs in contrast to M E mode NOTE The Privacy Mask function will be automatically disabled if the Image Flip function is enabled and the screen will show MASK WILL BE SET OFF M E...

Page 24: ...d during installation or maintenance the relative distance between the original set point and the check point can change Enable the Auto Calibration function so that the dome will automatically detect...

Page 25: ...selection ranges from 5 to 30 seconds To let the OSD menu stay on the screen please set this option to OFF SYSTEM RESET Two types of system reset can be implemented under this item SYSTEM RESET Select...

Page 26: ...to a view area for which you want to set a title STEP 2 Access the OSD menu go to MAIN PAGE 2 and select TITLE SETTING STEP 3 Select a number that will represent the view area STEP 4 Press the CAMERA...

Page 27: ...and then rotate the dome camera to a target shooting area point STEP 3 Press the CAMERA MENU key again to save the defined preset point Once the setup of a preset point is completed users can move th...

Page 28: ...unt of sequence points see the previous section is less than 64 points NOTE If not all 64 points are used please set the point following the last Sequence Point as the END PRESET POSITION so that the...

Page 29: ...ndless panning by setting the start point just like the end point START POINT Follow the description below to set the start position of the AUTOPAN path STEP 1 Move the cursor to the START POINT and p...

Page 30: ...rom 1 to 4 10 45 degrees sec RUN AUTOPAN After all settings related to Auto Pan are completed select this item to execute the Auto Pan function Press the CAMERA MENU key ENTER to run an Auto Pan path...

Page 31: ...ruise line when the setting is completed press ENTER to save the path RUN CRUISE After the Cruise setting is completed select this item to execute the Cruise function EXIT Exit the CRUISE setup menu a...

Page 32: ...etup menu RETURN TIME The Dome Camera starts to count down the selected RETURN TIME when the camera idles and it will execute the SELECT MODE function if the return time is up The RETURN TIME ranges f...

Page 33: ...nector Definition or to the Quick Guide NOTE If two or more alarm pins are triggered at the same time a smaller alarm pin number will have higher priority of being handled For example if Alarm 1 and A...

Page 34: ...is selected when an alarm takes place the Dome Camera will go to the selected preset position and stay there for a user defined period of time 1 127 seconds Always when an alarm takes place If other m...

Page 35: ...t zones Please refer to the following instructions to configure the parameters for each motion detection zone the so called Frames When motion is detected within a defined frame the flash warning noti...

Page 36: ...the monitored field THRESHOLD The Threshold range is adjustable from 1 255 The smaller the value the more sensitive it is i e 1 highest sensitivity 255 lowest sensitivity EXIT Exit the ALARM DETECT m...

Page 37: ...Maximally 8 masks can be displayed in one scene Please see the following description of the settings PRIVACY SWITCH Users can enable or disable the Privacy Mask function through this item Set this it...

Page 38: ...e to 0 can delete the selected mask CLEAR MASK Users can delete a preset mask zone with this item Please follow the steps listed below STEP 1 Select the mask zone that is to be erased e g 01 STEP 2 Pr...

Page 39: ...up the time in which each schedule point is to be executed MODE This is for setting the schedule function of the selected schedule point The options are listed as follows NONE No action will be execut...

Page 40: ...schedule with this item EXIT Exit the SCHEDULE menu and go back to MAIN PAGE 3 5 3 24 EXIT OSD To exit the OSD setup menu users can either select this item on the bottom of MAIN PAGE 3 or press the ES...

Page 41: ...sy installation To connect the connector box with other devices Use a RS 485 cable CAT 5 is recommended to complete RS 485 communication wiring with control devices such as DVRs and Control Keyboards...

Page 42: ...kilometers away Additionally the SDU can be installed eitherin a star or in a daisy chain configuration with up to 160 cameras see the diagrams below Its versatile installation configuration makes an...

Page 43: ...ugh a Pelco keyboard with built in D protocol and P protocol Please follow the instruction to operate the Swiftdome Camera through a keyboard with D and P protocols Cable Definition P Protocol Keyboar...

Page 44: ...of Preset 256 Number of Pattern 8 OSD Yes Alarm Inputs 4 Alarm Outputs 1 Regulation CE FCC RoHS Compliant Supply Voltage 12 VDC 24 VAC Operating Temperature 45 C 50 C Humidity less than 90 65 W Power...

Page 45: ...Preset 256 Number of Pattern 8 OSD Yes Alarm Inputs 4 Alarm Outputs 1 Regulation CE FCC RoHS Compliant Supply Voltage 12 VDC 24 VAC 20 W Power Consumption 1 6 kg Weight 131 x 226 mm Dimensions wxhxd 4...

Page 46: ...e standards in the following relevant provisions EC EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC Applied harmonised standards and technical specifications EN 55022 2006 EN 55024 1998 A1...