Pu
mped liquids
TPE E-circulators
6
11
Pumped liquids
Pumped liquids
Notes
Additional
information
Shaft seal
TP
Water
Groundwater
<+194 °F (+90 °C)
AUUE
>+194 °F (+90 °C)
BUBE
Boiler feed water
<+248 °F (+120 °C)
BUBE
District heating water
<+248 °F (+120 °C)
BUBE
Condensate
<+194 °F (+90 °C)
AUUE
>+194 °F (+90 °C)
BUBE
Softened water
C
<+194 °F (+90 °C)
AUUE
>+194 °F (+90 °C)
BUBE
Brackish water
G
pH>6.5,
+40 °F (+4 °C),
1000 ppm Cl
-
BUBE
AUUE
Coolants
Ethylene glycol
B, D, H
+122 °F (+50 °C),
50 %
AUUE
RUUE
Glycerine (glycerol)
B, D, H
+122 °F (+50 °C),
50 %
AUUE
RUUE
Potassium acetate
B, D, C,
H
+122 °F (+50 °C),
50 %
AUUE
RUUE
Potassium formate
B, D, C,
H
+122 °F (+50 °C),
50 %
AUUE
RUUE
Propylene glycol
B, D, H
AUUE
RUUE
Brine-sodium chloride
B, D, C,
H
+41 °F (+5 °C),
30 %
AUUE
RUUE
Synthetic oils
Silicone oil
B, E
BUBE
AUUE
Vegetable oils
Corn oil
B, F, E
BUBV
3)
AUUV
3)
Olive oil
B, F, E
<+176 °F
(80 °C)
BUBV
3)
AUUV
3)
Peanut oil
B, F, E
BUBV
3)
AUUV
3)
Grape seed oil
D, B, F,
E
BUBV
3)
AUUV
3)
Soya bean oil
B, F, E
BUBV
3)
AUUV
3)
Cleaning agents
Soap (salts of fatty
acids)
A, E, (F)
<+176 °F
(80 °C)
AUUE
(AUUV)
3)
Alkaline degreasing
agent
A, E, (F)
<+176 °F
(80 °C)
AUUE
(AUUV)
3)
Oxidants
Hydrogen peroxide
<+104 °C, <2 %
BUBE
AUUE
Salts
Ammonium bicarbonate
A
<+68 °F (+14 °C),
<15 %
AUUE
Calcium acetate
A, B
<+68 °F (+14 °C),
<30 %
AUUE
Potassium bicarbonate
A
<+68 °F (+14 °C),
<20 %
AUUE
Potassium carbonate
A
<+68 °F (+14 °C),
<20 %
AUUE
Potassium
permanganate
A
<+68 °F (+14 °C),
<10 %
AUUE
Potassium sulfate
A
<+68 °F (+14 °C),
<20 %
AUUE
Sodium acetate
A
<+68 °F (+14 °C),
<100 %
AUUE
Sodium bicarbonate
A
<+68 °F (+14 °C),
<2 %
AUUE
Sodium carbonate
A
<+68 °F (+14 °C),
<20 %
AUUE
Sodium nitrate
A
<+68 °F (+14 °C),
<40 %
AUUE
Sodium nitrite
A
<+68 °F (+14 °C),
<40 %
AUUE
Sodium phosphate (di)
A
<+212 °F (100 °C),
<30%
AUUE
Sodium phosphate (tri)
A
<+194 °F (90 °C),
<20%
AUUE
Sodium sulfate
A
<+68 °F (+14 °C),
<20%
AUUE
Sodium sulfite
A
<+68 °F (+14 °C),
<1%
AUUE
Alkalis
Ammonium hydroxide
<+212 °F (100 °C),
<30%
AUUE
Calcium hydroxide
A
<+212 °F (100 °C),
<10%
AUUE
Potassium hydroxide
A
<+68 °F (+14 °C),
<20%
AUUE
Sodium hydroxide
A
<+104 °F (40 °C),
<20%
AUUE
3)
The shaft seal is not standard, but available on request.
Pumped liquids
Notes
Additional
information
Shaft seal
TP