English (GB)
25
7.3.4
Setup
The "
Setup
" main menu contains menus for
pump configuration. These menus are
described in the following sections.
Check all pump settings after any change in the
"
Setup
" menu.
* These submenus are only displayed for specific
default settings and control variants. The
contents of the "
Setup
" menu also vary
depending on the operation mode.
7.4 Operation modes
Six different operation modes can be set in the
"
Setup
>
Operation mode
" menu.
•
Manual
, see section
•
Pulse
, see section
•
Analog 0-20mA
, see section
Analog 4-20mA
, see section
•
Batch (pulse-based)
, see section
•
Dosing timer cycle
, see section
•
Dosing timer week
, see section
7.4.1
Manual
In this operation mode, the pump constantly
doses the dosing flow set with the click wheel.
The dosing flow is set in l/h or ml/h in the "
Operation
"
menu. The pump automatically switches between the
units. Alternatively, the display can be reset to US
units (gph). See section
.
Fig. 18
Manual
mode
The setting range depends on the pump type:
* When
the
"
SlowMode
" function is active, the
maximum dosing flow is reduced, see section
TM
06 70
75 341
8
Setup
English
>
Pulse
>
❑
>
35.0 l
46:30
>
>
Actual flow
>
Off
>
❑
❑
>
>
❑
❑
>
❑
Off
>
>
>
>
>
>
Language
Operation mode
Pulse memory
*
Analog scaling
Batch volume
*
Dosing time
[mm:ss]*
Dosing timer cycle
*
Dosing timer week
*
Analog output
SlowMode
Stop after power failure
FlowControl active
*
FlowControl
*
Pressure monitoring
*
AutoFlowAdapt
*
Auto deaeration
Calibration
Diaphragm leak. detect.
*
Key lock
Display
Time+date
Bus
Inputs/Outputs
Basic settings
Section
6.3
7.4
7.4.2
7.4.3
7.4.4
7.4.4
7.4.5
7.4.6
7.5
7.6
7.7
7.8
7.8
7.9
7.11
7.12
6.5
7.13
7.14
7.15
7.16
7.17
7.18
7.19
T
M
06
70
77
29
16
Type
Setting range*
[l/h]
[gph]
DDA 60-10
0.075 - 60
0.0197 - 15.8
DDA 120-7
0.15 - 120
0.04 - 32
DDA 200-4
0.25 - 200
0.066 - 52.8
Operation
38.4
l/h
Manual
38.4l/h