Pumps with WIO sensor

Moisture switch

All pumps are fitted with a moisture switch as 
standard with the moisture switch being connected 
through the supply cable and connected to a 
separate circuit breaker.

Frequency converter operation

All SL1 and SLV pump types are designed for 
frequency converter operation to keep the power 
consumption at a minimum.
To avoid sedimentation in the pipes, operate the 
speed-controlled pump at a flow rate above 1 m/s.
In this product range, only negligible amount of 
bearing currents occurs during frequency converter 
operation.
For frequency converter operation, observe the 
following:

Before installing a frequency converter, calculate 
the lowest allowable frequency in the installation 
in order to avoid zero flow.

Do not reduce the motor speed to less than 50 % 
of rated speed.

Keep the flow velocity above 1 m/sec.

Let the pump run at rated speed at least once a 
day in order to prevent sedimentation in the 
piping system.

Do not exceed the frequency indicated on the 
nameplate to avoid motor overload.

Keep the power cable as short as possible. The 
peak voltage increases with the length of the 
power cable. See data sheet for the frequency 
converter used.

Use input and output filters on the frequency 
converter. See data sheet for the frequency 
converter used.

Use screened power cable if there is a risk that 
electrical noise can disturb other electrical 
equipment. See data sheet for the frequency 
converter used.

CAUTION
Electric shock

- For safe installation 

and operation of 
pumps equipped with a 
WIO sensor, an RC 
filter is recommended. 
If an RC filter is 
installed to avoid any 
kind of transients in the 
installation, the RC 
filter must be installed 
between the power 
connector and the 
pump.

Pumps for hazardous locations must be 
connected to a control box with a motor 
protection relay with IEC trip class 10. 

The thermal protection of explosion-proof 
pumps must not restart the pump 
automatically. This ensures protection 
against overtemperature in potentially 
explosive environments. In pumps with 
sensor this is done by removing the short 
circuit between terminals R1 and R2 in the 
IO 113. See Electrical data in the 
installation and operating instructions for 
IO 113 (net.grundfos.com/qr/i/98097396).

The separate motor-protective circuit 
breaker or controller must not be installed 
in potentially explosive environments.

CAUTION
Electric shock

Minor or moderate 
personal injury
- The motor-protective 

circuit breaker of the 
pump controller must 
include a circuit which 
automatically 
disconnects the power 
supply in case the 
protective circuit for the 
pump is opened.

If the motor is operated by a frequency 
converter, the temperature class of the 
explosion-proof pumps must be T3.

Summary of Contents for SL1 Series

Page 1: ...SL1 SLV 1 1 11 kW 50 60 Hz DIN Safety instructions GRUNDFOS INSTRUCTIONS Installation and operating instructions in other languages for 50 60 Hz net grundfos com qr i 96771279...

Page 2: ...installation and operating instructions Keep these safety instructions at the installation site for future reference Read this document before installing the product Installation and operation must co...

Page 3: ...e liquids large quantities of drainage and surface water domestic wastewater with discharge from toilets wastewater with a high content of fibres SuperVortex impeller municipal and commercial sewage a...

Page 4: ...e from 0 40 C TM07 5414 3919 Pos Description 1 Approvals 2 Explosion protection certificate No 3 Ex description 4 Type designation 5 Model number 6 Production code year and week 7 Enclosure class to I...

Page 5: ...f version 2 Number of poles 2 pole 4 4 pole 50 60 Frequency Hz 50 Hz 60 Hz 0B Voltage and starting method 3 x 400 415 V direct on line connection 0D 3 x 380 415 V direct on line connection 1D 3 x 380...

Page 6: ...eb mb IIB T3 T4 Gb with WIO sensor Transporting the product Handling and lifting the product Fig 3 Lifting bracket Direct drive pump without sensor CE 0344 II 2 G Ex db h IIB T4 Gb Direct drive pump w...

Page 7: ...ng the pump Carelessness during lifting or transport may cause injury to persons or damage to the pump WARNING Electric shock Death or serious personal injury Connect the pump to an external main swit...

Page 8: ...n the stator windings has a nominal switch temperature of 150 C and must guarantee the disconnection of the power supply The power supply must be reset manually 8 The control unit must protect the WIO...

Page 9: ...rushing of hands Death or serious personal injury Do not put your hands or any tool into the pump inlet or outlet port after the pump is connected to the power supply unless the pump has been switched...

Page 10: ...he atmosphere in the tank is not potentially explosive Inspect the oil level and condition every 3000 operating hours or at least once a year When the pump is new or after replacement of the shaft sea...

Page 11: ...sion proof pumps make sure that an external earth conductor is connected to the external earth terminal on the pump using a secure cable clamp Clean the surface of the external earth connection and mo...

Page 12: ...2 WARNING Electric shock Death or serious personal injury Make sure the earth and phase conductors are not mixed up Make sure the earth conductor is connected first Make sure that the product is earth...

Page 13: ...e cable DOL TM04 6884 0314 Standard version Thermal switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC t...

Page 14: ...switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC thermistor moisture switch and water in oil sensor 4...

Page 15: ...d version Thermal switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC thermistor moisture switch and wate...

Page 16: ...rd version Thermal switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC thermistor moisture switch and wat...

Page 17: ...break the circuit at 150 C The maximum operating current of the thermal switch is 0 5 A at 500 VAC and cos 0 6 The switch must be able to break a coil in the supply circuit Pumps with WIO sensor Pumps...

Page 18: ...ta sheet for the frequency converter used Use screened power cable if there is a risk that electrical noise can disturb other electrical equipment See data sheet for the frequency converter used CAUTI...

Page 19: ...onverter Frequency converter use can increase the wear on the shaft seal and bearings The noise level may increase See the installation and operating instructions for the frequency converter used The...

Page 20: ...l the cause of the faults have been identified and removed TM04 4527 1509 TM04 4528 1509 Operation Stop 6 min 4 min 10 min P t P t Operation Stop Compliance with the standards EN 60079 17 and EN 60079...

Page 21: ...ke sure that all rotating parts have stopped moving Maintenance work on explosion proof pumps must be carried out by Grundfos or an authorised service workshop This applies to both electric and hydrau...

Page 22: ...ard Minor or moderate personal injury Make sure that the lifting bracket is tightened before lifting the pump Always lift the pump by its lifting bracket or by a forklift truck if the pump is fixed on...

Page 23: ...pump must be switched off before working on the pump DANGER Crushing of hands Death or serious personal injury Before diagnosing any fault make sure that the fuses have been removed or the main switc...

Page 24: ...esclusiva responsabilit che i prodotti SL1 SLV ai quale si riferisce questa dichiarazione sono conformi alle seguenti direttive del Consiglio riguardanti il riavvicinamento delle legislazioni degli S...

Page 25: ...41 2003 except clause 25 8 A1 2004 A2 2010 EMC Directive 2014 30 EU For sensor versions the following standards are used EN 61326 1 2013 RoHS Directives 2011 65 EU and 2015 863 EU Standard used EN IEC...

Page 26: ...d clarons sous notre seule responsabilit que les produits auxquels se r f re cette d claration sont conformes aux lois ordonnances normes et sp cifications marocaines pour les quelles la conformit es...

Page 27: ...27 3 Zh 6 6 9 6 6 9 6 6 9 6 6 9...

Page 28: ...28 6 6 9 6 6 9 ZD 6 6 9 1 2 3 6 6 9 004 2011 010 2011 020 2011 D http net grundfos com qr i 98947334...

Page 29: ...of the construction product as set out in Annex V System 3 7 In case of the declaration of performance concerning a construction product covered by a harmonised standard T V Rheinland LGA Products Gmb...

Page 30: ...hla ovan mi vlastnostmi v bod 9 DE EU Leistungserkl rung gem Anhang III der Verordnung EU Nr 305 2011 Bauprodukte Verordnung 1 Einmalige Kennnummer des Produkttyps EN 12050 1 oder EN 12050 2 SL1 50 2...

Page 31: ...i f lgende Anvendte standarder EN 12050 1 2001 eller EN 12050 2 2000 SL1 50 10 Ydeevnen for den byggevare der er anf rt i punkt 1 og 2 er i overensstemmelse med den deklarerede ydeevne i punkt 9 EE EU...

Page 32: ...eclaraci n de prestaciones satisfacen las caracter sticas fundamentales y requisitos en materia de prestaciones descritos en Normas aplicadas EN 12050 1 2001 o EN 12050 2 2000 SL1 50 10 Las prestacion...

Page 33: ...u produit de construction comme stipul dans l Annexe V Syst me 3 7 En cas de d claration des performances d un produit de construction couvert par une norme harmonis e T V Rheinland LGA Products GmbH...

Page 34: ...ladu je s izjavljenom izvedbom u to ki 9 HU EU teljes tm nynyilatkozat a 305 2011 sz m EU rendelet III mell klet nek megfelel en p t si term k rendelet 1 A term kt pus egyedi azonos t k dja EN 12050 1...

Page 35: ...pplicate EN 12050 1 2001 oppure EN 12050 2 2000 SL1 50 10 Le prestazioni del prodotto identificato ai punti 1 e 2 sono conformi alle prestazioni dichiarate al punto 9 LT EB eksploatacini savybi deklar...

Page 36: ...s pa bas atbilst 9 punkt nor d taj m deklar taj m ekspluat cijas pa b m NL Prestatieverklaring van EU in overeenstemming met Bijlage III van verordening EU nr 305 2011 Bouwproductenverordening 1 Uniek...

Page 37: ...10 W a ciwo ci u ytkowe wyrobu okre lone w pkt 1 i 2 s zgodne z w a ciwo ciami u ytkowymi deklarowanymi w pkt 9 PT Declara o de desempenho UE em conformidade com o Anexo III do Regulamento UE N 305 2...

Page 38: ...50 2 2000 SL1 50 10 Performan a produsului identificat la punctele 1 i 2 este n conformitate cu performan a declarat la punctul 9 RS EU deklaracija o performansama u skladu sa Aneksom III propisa EU b...

Page 39: ...med EN 12050 1 p typskylten SL1 50 pumpar f r pumpning av fekaliefritt avloppsvatten m rkta med EN 12050 2 p typskylten 4 Tillverkarens namn registrerade f retagsnamn eller registrerade varum rke samt...

Page 40: ...00 SL1 50 10 Delovanje proizvoda identificiranega pod to kama 1 in 2 je skladno z deklariranim delovanjem pod to ko 9 SK Vyhl senie o parametroch EU v s lade s pr lohou III nariadenia E 305 2011 Naria...

Page 41: ...s na y nelik sistem veya sistemler Sistem 3 7 Uyumlu bir standart kapsam ndaki bir in aat r n yle ilgili performans beyan durumunda T V Rheinland LGA Products GmbH tan mlama numaras 0197 EN 12050 1 ve...

Page 42: ...med EN 12050 1 p navneplaten Pumper for pumping av avl psvann uten avf ring merket med EN 12050 2 p navneplaten 4 Navn registrert handelsnavn eller registrert varemerke og kontaktadresse for produsen...

Page 43: ...i m t ti u chu n h i h a T V Rheinland LGA Products GmbH s nh n di n 0197 Th c hi n ki m tra theo ti u chu n EN 12050 1 ho c EN 12050 2 SL1 50 theo h th ng 3 m t nh ng nhi m v c a b n th ba nh quy nh...

Page 44: ...50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 F...

Page 45: ...ozsk 4D 821 09 BRATISLAVA Phona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grund...

Page 46: ...9151 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2021...

Reviews: