Approvals
SL1 and SLV pumps have been tested by Dekra /
KEMA. The explosion-proof version hold two
examination certificates:
•
ATEX(EU): KEMA08ATEX0125X
•
IECEx: IECEx KEM08.0039X
Both certificates have been issued by Dekra.
Approval standards
ATEX:
IECEx:
IEC 60079-0:2017, IEC 60079-1:2014, IEC
60079-7:2017, IEC 60079-18:2017
The standard variants are approved by TÜV LGA
(notified body under the Construction Products
Directive) according to EN 12050-1 or EN 12050-2
as specified on the pump nameplate.
Australia and New Zealand
Explosion-proof variants for Australia and New
Zealand are approved Ex db IIB T3/T4 Gb (without
WIO sensor) or Ex db eb mb IIB T3/T4 Gb (with WIO
sensor).
Transporting the product
Handling and lifting the product
Fig. 3
Lifting bracket
Direct-drive pump without
sensor:
CE 0344
II 2 G Ex
db h IIB T4 Gb
Direct-drive pump with
sensor:
CE 0344
II 2 G Ex
db eb h mb IIB T4 Gb
Pump driven by frequency
converter without sensor:
CE 0344
II 2 G Ex
db h IIB T3 Gb
Pump driven by frequency
converter with sensor:
CE 0344
II 2 G Ex
db eb h mb IIB T3 Gb
Pump without sensor:
Ex db IIB T3, T4 Gb
Pump with sensor:
Ex db eb mb IIB T3,
T4 Gb
CAUTION
Crushing hazard
Minor or moderate
personal injury
- Make sure the pump
cannot roll or fall over.
WARNING
Crushing hazard
Death or serious
personal injury
- Always lift the pump by
its lifting bracket or by
a forklift truck if the
pump is fixed on a
pallet. Never lift the
pump by the power
cable, hose or pipe.
T
M
0
6
3
92
0 1
215
Lifting bracket