6.4 Description of fault indications

If a fault occurs, the symbol 

 will be visible, an audible alarm will be given by the buzzer and the fault code will be written by means of 

the 14-segment characters in the display. To see the kind of fault, if it is automatically reset and the code is not longer visible, open the 
fault log (see fig. 

16

). When you leave the fault log, the symbol 

 will disappear.

The last 20 faults are stored in the fault log as fault codes. The meaning of the fault codes are described in the table below:

Fault 

code

Meaning

Displayed 

text

Flashing 

symbols

Reset of fault 

indications

Description

Auto

Man

F001

Phase sequence 
failure

F001

(Only three-phase pumps)
The phase sequence between control board and power 
supply is wrong. See fig. 

17

.

F002

One phase 
missing

F002

(Only three-phase pumps)
One phase is missing.

F003

High liquid level

F003

The liquid level is high in relation to preset value.

F004

Sensor failure

SENSOR

-

Sensor signal out of range or lost.

F005

Overtemperature, 
pump 1

TEMP

Motor thermal switches connected to the controller will 
stop pump 1 in case of overheating.

F006

Overtemperature, 
pump 2

TEMP

Motor thermal switches connected to the controller will 
stop pump 2 in case of overheating.

F007

Overcurrent, 
pump 1

F007

Pump 1 is stopped if an overcurrent is measured for a 
certain period of time (blockage protection).

F008

Overcurrent, 
pump 2

F008

Pump 2 is stopped, if an overcurrent is measured for a 
certain period of time (blockage protection).

F011

Operating time 
exceeded, pump 1

F011

The pump has run for more than the allowed operating 
time, and the controller has stopped the pump for a 
defined 2cool-down period in order to prevent 
overheating. The operating time and cool-down period 
depend on the pump. See the duty type on the nameplate.
Check that the outlet valve is open.
Check that the non-return valve is functioning. A leaky 
non-return valve can allow liquid in the outlet pipe to flow 
back into the tank.
Remove any blockage from the vent hose at the pump 
outlet.

F012

Operating time 
exceeded, pump 2

F012

F013

External fault

EXT

-

An external level switch can be connected to the 
controller to give an alarm if basement outside the lifting 
station is flooded by groundwater or water from burst 
water pipe.

F014

Battery failure

BAT

-

The battery is empty and must be replaced.

F015

Relay or contactor 
does not open, 
pump 1

RELAY

Pump 1 receives a signal to stop, but does not react. This 
situation is detected by current measurement.

F016

Relay or contactor 
does not close, 
pump 1

RELAY

Pump 1 receives a signal to start, but does not react. This 
situation is detected by current measurement.

F017

Relay or contactor 
does not open, 
pump 2

RELAY

Pump 2 receives a signal to stop, but does not react. This 
situation is detected by current measurement.

F018

Relay or contactor 
does not close, 
pump 2

RELAY

Pump 2 receives a signal to start, but does not react. This 
situation is detected by current measurement.

F019

Communication 
fault

The display 

is off.

Communication fault between the main board and the 
display. As the display is off, you can only see the fault 
code via PC Tool. Check the ethernet cable between the 
main board and the display.

F117

F117

Communication fault between the main board and the 
display. The display is on and shows the fault code F117. 
Check the ethernet cable between the main board and the 
display.

Summary of Contents for Multilift MDG

Page 1: ...Multilift MOG MDG Installation and operating instructions GRUNDFOS INSTRUCTIONS Other languages http net grundfos com qr i 98127057...

Page 2: ...221 controller 11 6 1 Description of display 11 6 2 Setup menu 13 6 3 Information menu 14 6 4 Description of fault indications 15 7 Installation of lifting station 17 7 1 General description 17 7 2 Gu...

Page 3: ...er system and vortex impeller 2 Lifting bracket 3 Nameplate 4 Venting port DN 70 outer diameter 75 mm open 5 Screw cap for pressure tube and tank inspection opening 6 Vertical inlet DN 150 seal is acc...

Page 4: ...hazardous substances such as greasy wastewater from large scale catering establishments For drainage of greasy wastewater use a grease separator according to EN 1825 2 between a canteen or commercial...

Page 5: ...net Three phase motors are protected by a thermal switch in the windings and an additional thermal circuit breaker in the cabinet to cut out the motor in case of overload If the phase sequence for thr...

Page 6: ...The control box uses the analogue signal to start and stop the pump and to indicate high water level alarm The pressure tube is fixed underneath the screw cap and can be taken out for maintenance ser...

Page 7: ...nnection of thermal switches and a runtime limitation motor protection via operation time limitation with subsequent emergency operation Normal operating times are max 90 seconds with pipework DN 32 a...

Page 8: ...mmon alarm output which is a potential free changeover contact can be used to forward the alarm signal to a control room by means of an external power source Type key LC 221 controller Nameplate LC 22...

Page 9: ...are described in section 6 1 Description of display Operating buttons pos 2 The level controller is operated by the operating buttons placed under the display The function of the operating buttons is...

Page 10: ...Potential free changeover contacts NO NC with max 250 V 2 A Attention Connect these terminals to supply network potential or low voltage but do not mix the two X11 9 Terminals for high water level ala...

Page 11: ...ible if the level controller detects a fault and the fault will be written into the fault log After you have entered the fault log the symbol will switch off See section 6 3 Information menu Setup The...

Page 12: ...fault in pump 1 The symbol is visible when pump 1 is running and flashes when pump 1 has a fault In case of fault it can be combined with other symbols or fault codes in the display Pump operation an...

Page 13: ...sing the button Enter values or select settings from a list by means of the buttons and Save the settings by pressing the button See also fig 15 The following settings can be made start level rated cu...

Page 14: ...enu by means of the buttons and Select the desired menu item by pressing the button See also fig 16 In the information menu the following data can be read fault indications operating hours number of s...

Page 15: ...g time and the controller has stopped the pump for a defined 2cool down period in order to prevent overheating The operating time and cool down period depend on the pump See the duty type on the namep...

Page 16: ...g is open If automatic resetting was selected in menu setup the red LED and the symbol will disappear and the buzzer will be deactivated again after the fault has disappeared has been removed or the O...

Page 17: ...observed 7 1 1 Installation sketch Fig 18 Installation sketch TM05 2143 4511 4 6 2 1 5 3 Pos Accessories Product number 1 Socket seal DN 100 97726942 2 Socket seal DN 50 98079669 3 Diaphragm pump 1 1...

Page 18: ...ation for black wastewater must be vented above roof level However it is permitted to lead the ventilation as a secondary ventilation into the main building ventilation system Special vent valves acce...

Page 19: ...Optional DN 150 inlet disk adjustable from 207 to 279 mm above the floor to the middle of the inlet pipe Fig 21 Untightened screw in outer ring Fig 22 Plugging the main inlet 3 Prepare optional inlets...

Page 20: ...be ensured if a distance of approx 3 cm is left between the vent pipe end and the vent port 8 Connect the diaphragm pump optional Fit the diaphragm pump on the outlet side To facilitate servicing of...

Page 21: ...ugh the cable entries and gaskets The power outlet must be placed near the cabinet as the controller is supplied with a 1 5 m cable Maximum backup fuse is stated on the controller nameplate Warning Wh...

Page 22: ...of a swimming pool is connected to Multilift MOG or MDG The preset value is 5 seconds Maintenance interval The maintenance service interval can be set to 0 3 6 or 12 months and is indicated in the SER...

Page 23: ...peration Replace defective ball bearings A general overhaul of the pump is usually required in case of defective ball bearings or poor motor function This work must be carried out by the manufacturer...

Page 24: ...G or MDG Fig 30 Removing the level sensor 10 4 Contaminated lifting station or components If Grundfos is requested to service the lifting station Grundfos must be contacted with details about the pump...

Page 25: ...and the red indicator light for fault is flashing The fault indication in the display is RELAY and the fault code is F018 Check the pump and tank as well as the setting of the motor protective circuit...

Page 26: ...ocked clean the vent hole c The thermal switch has cut out the pump The pump and thermal switch symbols on the display are flashing and the red indicator light for fault is permanently on The fault in...

Page 27: ...iron Impeller PPE PS Pump shaft Stainless steel DIN W Nr 1 4301 Motor cable Polychloroprene O rings NBR rubber Controller Voltage variants rated voltages 1 x 230 V 3 x 230 V 3 x 400 V Voltage toleran...

Page 28: ...I MOG 12 3 2 3 x 400 V 3 1 21 2750 CEE 3P N E 16 A MOG 15 3 2 3 x 230 V 2 3 1 5 6 6 36 2700 2 CEE 3P E 16 A MOG 15 3 2 3 x 400 V 3 8 21 2700 CEE 3P N E 16 A MOG 26 3 2 3 x 230 V 3 7 2 6 9 2 57 2870 2...

Page 29: ...Appendix 29 Appendix 1 Fig A Dimensional sketch MOG TM05 0672 1011...

Page 30: ...Appendix 30 Fig B Dimensional sketch MDG TM05 0443 1011...

Page 31: ...53 428 5005 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava b...

Page 32: ...splayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2018 Grundfos Holding A...

Reviews: