6.2 Setup menu
All settings are preset except for the start level. The start level
depends on the inlet height and must be set during the startup
phase. See section
. However, in case
adjustments are required, settings can be made via the setup
menu. To open the setup menu, mark the symbol
using the
button
and press the button
. Navigate through the menu by
means of the buttons
and
. Select the desired menu item by
pressing the button
. Enter values or select settings from a list
by means of the buttons
and
. Save the settings by pressing
the button
. See also fig.
The following settings can be made:
• start level
• rated current
• stop delay
• start delay
• alarm delay
• time for maintenance
• alarm reset (manually or automatically)
• reset to factory settings.
Fig. 15
Menu structure for setup menu
TM
06
667
6 201
6
L_01 Start level [mm]
Setup menu
3.8
I_02 Rated current [A]
T_01 Stop delay [sec.]
T_02 Start delay [sec.]
2
0
T_03 Alarm delay [sec.]
5
Manual/
Automatic
0, 3, 6, 12
EXIT
EXIT Back to main menu
G_01 Reset to factory settings
A_01 Reset alarm
M_01 Maintenance interval [month]
180
250
315