9
(
Q
J
OLV
K
8
6
5.1 Voltage switching
5.1.1 Fitting the voltage converter
See fig. 7.
1. Check the voltage indicated on the side of
the voltage converter.
2. Turn the indicator so that the desired voltage
points towards the side with the "M" lock
catch.
3. The arrow on the converter next to the
required voltage must be aligned with the "F"
arrow on the housing.
4. Push the coverter into position until the
reference catch "M" clips in place.
Fig. 7
Voltage switching
6. Operation
6.1 Startup
Before starting up, check that the pump is
properly primed. See fig. 8.
Fig. 8
Pump must be primed before
startup
Fill it completely with clean water by means of
the hole provided after having removed the filler
cap on the pump body. This ensures that the
mechanical seal is well lubricated and that the
pump immediately starts to work regularly.
The filling cap must then be screwed back on
carefully.
Warning
Do not pull the voltage switching
plug by the wires. Use only a firm
hand grip around the voltage
switching plug to avoid damage.
TM
05 1
185
24
11
Warning
Do not start the pump until it has
been completely filled with liquid.
Dry operation causes irreparable
damage to the mechanical seal.
&
&DXWLRQ
The pump should not be started
more than 20 times in one hour
so as not to subject the motor to
excessive thermal shock.
T
M
0
5
1
1
83
241
1
Summary of Contents for JP Booster PS Series