![Grundfos DMX 221 Installation And Operating Instructions Manual Download Page 45](http://html1.mh-extra.com/html/grundfos/dmx-221/dmx-221_installation-and-operating-instructions-manual_2271278045.webp)
•
maximum counterpressure
•
dosing medium with viscosity and density similar to those of water
•
flooded suction 0.5 m
•
fully deaerated dosing head
•
stroke length 100 %
•
three-phase 400 V motor.
Pump type
Stroke volume
Maximum stroke rate
[cm
3
]
50 Hz
60 Hz
[n/min]
[n/min]
DMX 4-10
2.2
29
35
DMX 7-10
3.8
29
35
DMX 9-10
4.9
29
35
DMX 12-10
6.9
29
35
DMX 17-4
10.4
29
35
DMX 25-3
16
29
35
DMX 7.2-16
1.9
63
75
DMX 8-10
2.2
63
75
DMX 14-10
3.8
63
75
DMX 18-10
4.9
63
75
DMX 26-10
6.9
63
75
DMX 39-4
10.4
63
75
DMX 60-3
16
63
75
DMX 13.7-16
1.9
120
144
DMX 16-10
2.2
120
144
DMX 16-12
2.2
120
144
DMX 27-10
3.8
120
144
DMX 27-12
3.8
120
144
DMX 35-10
4.9
120
144
DMX 50-10
6.9
120
144
DMX 75-4
10.4
120
144
DMX 115-3
16
120
144
Outlet pressure
Parameter
Value
Minimum counterpressure
1 bar at the pump outlet valve
Accuracy
The values in the table below apply to the following conditions:
DMX 221 | |
45