3
Eng
lish (US
)
Fig. 1
CRN MAGdrive pump
5. Technical data
Liquid temperature:
–4 °F to +248 °F (–30 to 120 °C).
Maximum system pressure: 362 psi (25 bar).
Viscosity:
0.25 to 100 centipoise.
Minimum flow rate
The pump
must never
run without flow. The curve below shows
the minimum flow rate as a percentage of the rated flow rate in
relation to the liquid temperature.
Fig. 2
Minimum flow rate
6. Type key
See also the installation and operating instructions of CR, CRI,
CRN.
7. Mechanical installation
Before installation, check that
• the pump and its components are as ordered.
• no visible parts have been damaged.
7.1 Installation of pump
The pump must be installed and put into operation as described
in the installation and operating instructions of CR, CRI, CRN.
It is advisable to protect CRN MAGdrive pumps against dry run-
ning by installing a flow switch, pressure switch or a LiqTec® sen-
sor close to the pump. The delay of the dry-running protection
must be maximum 15 seconds.
7.2 Connection of sensor
A pressure sensor or a Grundfos LiqTec dry-running protection
can be fitted in the threaded hole in the pump head.
8. Electrical connection
The pump must be installed as described in the installation and
operating instructions of CR, CRI, CRN.
Pumps with motors of 25 and 30 Hp and 4-pole motors 1.5 Hp
(1.1 kW) and above must be started via a soft starter.
8.1 Motor protection
As minimum the motor must be connected to an effective elec-
tronic motor protection with instantaneous release when the max-
imum setting of the current is reached. If a soft starter or fre-
quency converter is used it must also be with instantaneous
release.
T
M
0
3 9
119
34
07
Pos.
Description
1
Motor
2
Magnetic drive
3
Pump
TM
02
75
38
37
03
1
3
2
40
60
80
100 120 140 160 180
t [°F]
0
10
20
30
Qmin
[%]
40
60
80
100 120 140 160 180
t [°C]
140 176 212 248 284 320 356
104
Example
CRN
5
-13
-M
-F -G -E
Type range
Rated flow rate in m³/h
Number of impellers
Code for pump version
M:CRN pump with magnetic drive
Code for pipe connection
CA:FlexiClamp
CX:Tri Clamp
F:DIN flange
G:ANSI flange
J:JIS flange
P:PJE coupling
Code for materials
G:Wetted parts EN 1.4401/AISI 316
Code for rubber parts of pump
E:EPDM
F:FXM (Fluoraz
®
)
K:FFKM (Kalrez
®
)
V:FKM (Viton
®
)
Installation and operation must comply with local
regulations and accepted codes of good practice.
Description
Dimension
Threaded connection:
½" NPT
Max. installation length, sensor:
.787 in. (20 mm)
Grundfos.bk Page 3 Tuesday, August 23, 2011 11:33 PM