CONTENTS

Page

1.

Symbols used in this document

4

2.

General description

4

3.

Commissioning

4

4.

Pumped liquids

4

5.

Technical data

5

5.1

Sound pressure level, inlet pressure and temperatures 5

6.

Preparation

5

7.

Installation

5

7.1

BMP hp feed pump

5

7.2

X-Changer 5

7.3

BM hp circulation pump

6

8.

Pipe connection

6

8.1

Inlet and discharge pipes

6

9.

Electrical connection

6

9.1

BMP hp feed pump

6

9.2

BM hp circulation pump

7

10.

Before starting the BMPX

8

11.

Start-up and operation

9

11.1

BMPX

9

11.2

Flow control and balancing

9

11.3

High-pressure flow control

9

11.4

Low-pressure flow control

9

11.5

Operation settings

9

11.6

Balancing the X-Changer 

9

11.7

BM hp circulation pump

10

12.

Checking the operation of the BMPX system

10

13.

Maintenance

10

14.

Motor bearings

10

15.

Shut-down procedure

10

16.

Periods of inactivity

10

16.1

Start-up after a period of inactivity

10

17.

Limitations to operation, BM hp circulation pump

11

17.1

Cooling

11

18.

Fault finding chart

12

18.1

BMP hp feed pump

12

18.2

BM hp circulation pump

13

18.3

X-Changer

14

19.

Checking motor and cable

15

20.

Disposal

15

1. Symbols used in this document

2. General description

The Grundfos BMPX booster system is designed for desalination 
of sea water in reverse osmosis systems, so-called SWRO 
systems (SWRO = Sea Water Reverse Osmosis). The design of 
the system offers high energy recovery.

The BMPX booster system consists of:

BMP hp feed pump (hp = high-pressure)

BM hp circulation pump (hp = high-pressure)
with Variable-Frequency Drive (VFD)
(the pump is installed in a sleeve)

X-Changer.

The Grundfos BMP hp feed pump is a piston pump, i.e. the flow is 
proportional to the motor speed. The pressure is equal to the 
back-pressure. Consequently, it is important that the maximum 
pump pressure is not exceeded.

The BMPX units are supplied from factory in boxes in which they 
must remain until they are to be installed. The units are ready for 
installation.

3. Commissioning

Commissioning of the BMPX booster system must be carried out 
by competent and certified Grundfos employees to ensure long 
and trouble-free operation.

The commissioning includes training on site of the people 
maintaining and monitoring the system.

4. Pumped liquids

Thin, non-explosive liquids, not containing solid particles or 
fibres. The liquid must not chemically attack the materials of the 
BMPX units. In case of doubt, contact Grundfos.

The raw water to the BMP hp feed pump and X-Changer must be 
filtered to maximum 5 microns abs (abs.

β

10

 > 5000).

The BMPX system must never operate with water/liquid 
containing substances removing surface tension, e.g. soap. If this 
type of detergent is used for cleaning the system, the water/liquid 
must be led around the units via a bypass.

Fig. 1

BMPX booster system

Warning

Prior to installation, read these installation and 
operating instructions. Installation and operation 
must comply with local regulations and accepted 
codes of good practice.

Warning

If these safety instructions are not observed, 
it may result in personal injury!

Caution

If these safety instructions are not observed, 
it may result in malfunction or damage to the 
equipment!

Note

Notes or instructions that make the job easier 
and ensure safe operation.

Note

If this requirement is not met, the BMPX warranty 
will be invalidated.

Warning

The BMPX booster system is designed solely for 
brackish water and sea water and must not be 
used for other liquids.

Pump type

Recommended pumped liquids

BMP

• Raw  water
• potable water 
• groundwater
• surface water (lakes and rivers)

Note

During transportation and storage, the pumps 
must never be preserved with liquids which are 
aggressive to the pump materials.

T

M

03

 58

16

 40

06

Permeate

Concentrate
(brine)

BMP hp 
feed 
pump

BM hp circulation pump

X-Changer

Sea-water feed pump

Summary of Contents for BMPX

Page 1: ...BMPX GRUNDFOS INSTRUCTIONS Installation and operating instructions ...

Page 2: ...nsiglio concernente il ravvicinamento delle legislazioni degli Stati membri CE relative a Macchine 98 37 CE Materiale elettrico destinato ad essere utilizzato entro certi limiti di tensione 2006 95 CE Standard usati EN 60335 1 2002 e EN 60335 2 41 2003 Compatibilità elettromagnetica 2004 108 CE Standard usati EN 61000 6 2 e EN 61000 6 3 Declaración de Conformidad Nosotros Grundfos declaramos bajo ...

Page 3: ...s 4 Montage und Betriebsanleitung 16 Notice d installation et d entretien 29 Istruzioni di installazione e funzionamento 41 Instrucciones de instalación y funcionamiento 53 Οδηγίες εγκατάστασης και λειτουργίας 65 Monterings og driftsinstruktion 79 ...

Page 4: ...e BMPX units are supplied from factory in boxes in which they must remain until they are to be installed The units are ready for installation 3 Commissioning Commissioning of the BMPX booster system must be carried out by competent and certified Grundfos employees to ensure long and trouble free operation The commissioning includes training on site of the people maintaining and monitoring the syst...

Page 5: ...Changer Check that all nuts are tightened 7 Installation The BMP hp feed pump and X Changer are delivered separately without any kind of base frame The installation must be carried out according to local regulations and in such a way that proper and reliable operation can be obtained 7 1 BMP hp feed pump The inlet port is marked with an I and the discharge port with an O Fig 2 BMP hp feed pump and...

Page 6: ...ms for the motor protection starter and monitoring devices used See fig 7 The electrical connections must be made in the terminal box Fig 7 Wiring diagram BMP hp feed pump The required voltage quality measured at the motor terminals is 10 6 of the rated voltage during continuous operation including variation in the supply voltage and losses in cables It must be checked that there is voltage symmet...

Page 7: ...ice 9 1 4 Thermistor If thermistors are used as protection they must be connected to terminals T1 and T2 before start up See fig 7 9 2 BM hp circulation pump The electrical connection must be carried out by an authorised electrician in accordance with local regulations The required voltage quality measured at the motor terminals is 10 6 of the rated voltage during continuous operation including va...

Page 8: ...unit should be set as above but the maximum setting should be as follows Starter overload setting rated current I1 1 ISFA x 0 58 The maximum permissible run up changeover time for star delta starting is 2 seconds 10 Before starting the BMPX Check the following Electricity supply in accordance with nameplate Pipework according to the diagram fig 12 Functionality of the solenoid valve BM hp circulat...

Page 9: ...ge flow equals the high pressure brine inlet flow 11 4 Low pressure flow control The low pressure reject water valve V3 on the discharge side of the system must be adjusted to control the flow rate of the low pressure sea water inlet and low pressure brine discharge This valve also adds back pressure on the X Changer required to prevent destructive cavitation The low pressure sea water inlet flow ...

Page 10: ...rating conditions the operating life of the motor ball bearings is approx 20 000 operating hours After that period the bearings must be replaced The new bearings must be filled with grease 15 Shut down procedure See section 16 Periods of inactivity for precautions to be taken when shutting down the system 1 If operated by variable frequency drive speed down the BMP hp feed pump P3 until the system...

Page 11: ...must be observed to ensure sufficient cooling of the motor Recommended flow rates at 25 C 77 F Type of BM hp m3 h US GPM 50 Hz 60 Hz 50 Hz 60 Hz BM 5A 3 2 5 6 3 3 6 4 14 25 14 28 BM 8A 5 9 5 7 9 22 48 30 40 BM 17 8 24 8 29 35 106 35 128 BM 30 15 38 18 45 66 167 79 198 Maximum permissible liquid temperature Motor Maximum liquid temperature Minimum flow velocity past the motor Minimum flow C F m s f...

Page 12: ...ons 9 2 2 Motor protection and 11 Start up and operation c The magnetic coil in the motor starter contactor is defective not cutting in Replace the coil Check the coil voltage d The control circuit has cut out or is defective Check the control circuit and the contacts in the monitoring devices low pressure switch level switch etc e The motor supply cable is defective Check motor and cable See sect...

Page 13: ...unit has tripped out Reset the starter overload If it trips out again the voltage should be checked c The magnetic coil of the motor starter contactor is short circuited not cutting in Replace the coil Check the coil voltage d The control circuit has cut out or is defective Check the control circuit and the contacts in the monitoring devices pressure switch flow switch etc e The motor supply cable...

Page 14: ...an high pressure flow resulting in mixing and high feed water salinity See section 11 6 Balancing the X Changer 3 High salinity in high pressure sea water feed stream a Unbalanced system See section 11 6 Balancing the X Changer b A jammed or stalled rotor short circuits high pressure reject water with high pressure feed water No exchange occurs no audible rotation See fault number 5 4 Low pressure...

Page 15: ...the phase with the highest amp consumption and the one with the lowest amp consumption must not exceed 10 of the lowest amp consumption If so or if the current exceeds the rated current check these possible faults A damaged pump is causing the motor to be overloaded Pull the pump out of the sleeve for overhaul The motor windings are short circuited or partly disjointed Too high or too low supply v...

Page 16: ... to support any warranty claims Initial data must be submitted within 24 hours of start up Product no Installation date Company your ref Country Type Start of operation City VFD Soft start Brand Date Amb temp Liquid temp Inlet pressure Discharge pressure Flow Current A Voltage V Comments ...

Page 17: ...o support any warranty claims Initial data must be submitted within 24 hours of start up Product no Installation date Company your ref Country Type Start of operation City VFD Soft start Brand Date Amb temp Liquid temp Feed flow pressure Discharge flow pressure Current A Voltage V Comments ...

Page 18: ...a must be submitted within 24 hours of start up Model of X Changer Company your ref Country Start of operation City Serial number Units please circle bar m3 h psi gpm Date Total hours HP inlet pressure HP discharge pressure LP inlet pressure LP discharge pressure HP flow LP flow LP inlet salinity HP discharge salinity ...

Page 19: ...94 ...

Page 20: ...Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFO...

Page 21: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96770338 1007 156 ...

Reviews: