Menu items
Settings / remarks
N. O.
Contact closed in the event of a
malfunction.
Programmable
input function
Leakage detection
– factory setting
If a leakage is detected at the
installation site of the softliQ system
via the water sensor, the message
"Leakage at the softliQ installation site"
is displayed.
Regeneration lock
The regeneration lock is active as long
as the contact at the programmable
input is closed; manually released and
automatic regenerations after a power
failure take priority. A regeneration that
has already been started is not
cancelled.
Release of regeneration
Start of a partial regeneration if the
contact at the programmable input
closes.
Generate system data
overview*
Start
When there is a connection to the
access point, all parameter settings
can be loaded into the smartphone
and a *.pdf document generated.
* Function planned
6.9
Sending an email if there is a malfunction
If your softliQ water softener is connected to your user account in the Grünbeck Cloud, you
will be notified by e-mail in the event of a fault.