![Grunbeck softliQ:MD Series Operation Manual Download Page 34](http://html1.mh-extra.com/html/grunbeck/softliq-md-series/softliq-md-series_operation-manual_2270832034.webp)
Operation
34 | 80
B
A
_
T
D3
-B
M
0
0
2
e
n
_
0
0
4
_
so
ft
liQ
-MD
6.1.3
Information display
Figure
Explanation
Blue symbol
The water softener is working properly.
Both exchangers are in operation.
The system capacity declines from the top downwards between
2 regenerations. One bar corresponds to 20 %. The bright bars
indicate the available system capacity (= soft water volume still
available).
Blue and grey symbol
The water softener is working properly.
Exchanger 1 is in operation, exchanger 2 is being regenerated.
The bars correspond to the following regeneration steps from the
bottom upwards:
•
Filling brine tank (lowest bar)
•
Salting
•
Slow rinse
•
Backwash
•
Washing out (uppermost bar)
Current flow rate
The current flow rate is displayed as a numerical value and in the
form of a "tachometer" (blue-coloured circle segments). If the
nominal flow of the system is exceeded, the circular segments
appear in red.
Function
The selected mode of operation appears in a green circle
segment.
Perform maintenance
since … days
Yellow symbol
Maintenance due!
Notify Grünbeck's technical service / authorised service company.
Leak at the
softliQ installation location
Yellow symbol
Check system location (detection via water sensor) for water
leakage and close main valve of domestic water installation if
necessary.
… days
Yellow symbol
The supply of regeneration salt is running low. The expected time
for the salt to last in days is displayed. Refill salt tablets.