background image

 

About this manual 

 

 

 

5 | 44 

B

A

_

T

D3

-A

K

0

0

0

en

_035

 

 

 

This symbol identifies important information about the product or 
its handling. 

 

 

 

This symbol identifies work that is only allowed to be carried out 
by specialist installers. In Germany, the installation company 
must be registered in an installation directory of a water supply 
company acc. to §12(2) AVB Wasser V (German Ordinance on 
General Conditions for the Supply of Water). 

 

1.5  Typographical conventions 

The following typographical conventions are used in this manual: 

1.5.1  Instructions 

Single-step instructions or instructions in which the sequence is 

unimportant are indicated as follows: 

►  Action 

Multi-step instructions in which the sequence must be complied 
with are indicated as follows: 

1. 

First action 

First step of the first action 

Second step of the first action 

2. 

Second action 

Results of an instruction are indicated as follows: 

» 

Result 

Summary of Contents for pureliQ:K

Page 1: ...We understand water Filter Fine filter pureliQ K pureliQ KD Operation manual...

Page 2: ...the copyright to this manual No part of this manual may be reproduced in any way without the written permission of Gr nbeck Wasseraufbereitung GmbH nor may any part be processed duplicated or dissemi...

Page 3: ...components 14 3 3 Functional description 15 4 Installation 16 4 1 Requirements for the installation site 16 4 2 Checking the scope of supply 17 4 3 Installing the product 18 5 Start up 20 5 1 How to...

Page 4: ...alist installers and owners users 1 3 Storage of documents Keep this manual and all other applicable documents so that they are available when needed Make sure that your specialist installer enters th...

Page 5: ...sser V German Ordinance on General Conditions for the Supply of Water 1 5 Typographical conventions The following typographical conventions are used in this manual 1 5 1 Instructions Single step instr...

Page 6: ...Lists List symbols used First list point level 1 First bullet point level 2 Second bullet point level 2 Second list point level 1 1 6 Validity of the manual This manual applies to the following produc...

Page 7: ...er below in order to have the necessary data handy whenever necessary Item Designation Item Designation 1 Observe operation manual 2 SVGW mark of conformity registered 3 DVGW mark of conformity regist...

Page 8: ...About this manual 8 44 BA_TD3 AK000en_035 Serial no ________________...

Page 9: ...sequence may be water damage Only use genuine spare parts for maintenance or repair If unsuitable spare parts are used the warranty for your product will be void Comply with the hygiene instructions i...

Page 10: ...oidance The following signal words are defined depending on the degree of danger and can be used in this document DANGER means that serious or fatal injuries will occur if the corresponding precaution...

Page 11: ...g water for human consumption VDI 6023 Part 6 2 4 Responsibilities of the specialist installer Comply with the following instructions to ensure the proper and safe functioning of the product Only perf...

Page 12: ...d in this manual Do not carry out any activities that are explicitly marked for a specialist installer Only use this product as intended Make sure that the required inspection and maintenance work is...

Page 13: ...ure range The filters are not suitable for circulation water that is treated with chemicals They are neither suitable for oils greases solvents soaps and other lubricating media nor for the separation...

Page 14: ...components Item Designation Item Designation 1 Water meter screw connection 2 Click connection flange 3 Pressure reducer handwheel 4 Month display 5 Pressure gauge 6 Support fabric 7 Filter element 8...

Page 15: ...pure water outlet Thus foreign particles of 100 m in size are retained Depending on their size and weight the foreign particles either stick to the filter element or they fall straight down into the f...

Page 16: ...806 2 and DIN 1988 200 in the cold water line downstream of the water meter and upstream of distribution lines or the devices to be protected Item Designation Item Designation 1 Shut off valve 4 1 Re...

Page 17: ...available an appropriate safety device has to be installed to avoid water damage We recommend using a protectliQ A The installation site must be well accessible for maintenance purposes 4 2 Checking...

Page 18: ...ding to DIN VDE 0100 540 Use suitable tools for assembly and be careful not to scratch the housing with your tool The transparent plastic film serves as transport and dirt protection We recommend leav...

Page 19: ...ow direction given on site 3 Check the flow direction given on site 4 Rotate the click type connection flange to the position suitable for your flow direction marking on click type connection flange 5...

Page 20: ...filter as far as it will go The filter is vented 3 Check the filter for leaks The filter is in operation 5 2 Setting the month display In order not to miss a maintenance date you can set the next date...

Page 21: ...he pressure reducer is 4 bar You can change this value as follows 1 Open the withdrawal point 2 Set the desired after pressure on the handwheel for pressure reducer by turning it 3 Read off the measur...

Page 22: ...When handing over the product proceed as follows 1 Inform the owner user how the filter works 2 Hand over all documents to the owner user for keeping 3 Use the manual to brief the owner user and answ...

Page 23: ...n and replacement of the filter element Inspection and maintenance of a filter is prescribed in the DIN EN 806 5 standard Regular maintenance ensures trouble free hygienic operation A maintenance cont...

Page 24: ...ng maintenance Owner user or specialist installer 6 3 Inspection According to DIN EN 806 5 the owner user has to inspect the filters every 2 months Check the installation for leaks refer to chapter 5...

Page 25: ...Cleaning inspection maintenance 25 44 BA_TD3 AK000en_035 6 Unscrew the filter bell by hand You have uncovered the used filter element and can change it as described below 1 2...

Page 26: ...hygienic reasons the new filter element must not be touched with bare hands 5 Slide the filter element in the foil over the support fabric 6 Pull off the foil downwards without touching the filter ele...

Page 27: ...sk of inadequate hygiene It is essential to discard used filter elements Designation Order no 100 m filter element 2x 101 272e 6 6 Wearing parts NOTE Danger of damaging the system if unsuitable wearin...

Page 28: ...s 6 7 1 Service kits for fine filter pureliQ K Item Designation Item Designation 1 Support fabric O ring 2 Support fabric 3 Filter cylinder 4 Cylinder O ring Designation consisting of Order no Recomme...

Page 29: ...ng 3 Support fabric 4 Filter cylinder 5 Cylinder O ring 6 Pressure reducer Designation consisting of Order no Recommended replacement interval Service kit III Set of seals Support fabric Pressure redu...

Page 30: ...n maintenance 30 44 BA_TD3 AK000en_035 6 8 Spare parts NOTE Risk of damaging the system when unsuitable spare parts are used Risk of functional impairment malfunctions and loss of warranty Only use ge...

Page 31: ...ment is dirty Change the filter element Taste of the treated water negatively affected Inappropriately long period of non use standstill Draw off water for a few minutes Change the filter element Soli...

Page 32: ...sal Do not dispose of the packaging the product and or the accessories with the domestic waste Comply with the applicable national regulations for disposal Make sure that the packaging the product and...

Page 33: ...imensions and weights A Installation height up to centre of connection mm 235 B Installation length with without screw connection mm 185 100 182 100 191 100 C Min distance to wall mm 50 D Installation...

Page 34: ...h 6 5 8 5 9 1 Pore size m 100 Largest smallest pore size m 120 80 Nominal pressure PN 16 General Water temperature C 5 30 Ambient temperature C 5 40 DVGW registration number pending SVGW certificate n...

Page 35: ...d weights A Installation height up to centre of connection mm 235 B Installation length with without screw connection mm 185 100 182 100 191 100 C Min distance to wall mm 50 D Installation depth up to...

Page 36: ...m h Flow rate as per DIN EN 1567 m h 2 3 3 6 5 8 KV value m h Pore size m 100 Largest smallest pore size m 120 80 Nominal pressure PN 16 General Water temperature C 5 30 Ambient temperature C 5 40 DV...

Page 37: ...ding does not exceed the maximum specified value whichever value is lower Upper filtration fineness the number indicates the particle size of a material in m which passes through the filter under test...

Page 38: ...Operation log 38 44 BA_TD3 AK000en_035 11 Operation log Product designation Fine filter pureliQ ____ Order no 101 ___ Serial no ________________ Date Work performed Signature...

Page 39: ...Notes 39 44 BA_TD3 AK000en_035 Notes...

Page 40: ...Notes 40 44 BA_TD3 AK000en_035 Notes...

Page 41: ...Notes 41 44 BA_TD3 AK000en_035 Notes...

Page 42: ...r element14 15 25 26 27 31 33 35 37 Filtration 13 I Inspection 12 23 24 Installation 9 11 12 16 19 24 M Maintenance 4 9 11 12 20 23 24 26 Malfunction 31 P Pressure reducer 13 14 15 21 29 S Service kit...

Page 43: ......

Page 44: ...Gr nbeck Wasseraufbereitung GmbH Josef Gr nbeck Str 1 89420 Hoechstaedt Germany For more Information go to www gruenbeck com 49 9074 41 0 49 9074 41 100 info gruenbeck com www gruenbeck com...