Malfunction
Explanation
Remedy
The water pressure at the
withdrawal point is too low
(pressure loss too high).
The shut-off valves are not
open completely.
Open the shut-off valves
completely.
The filter cartridge is
fouled.
Change the filter cartridge.
Taste of the treated water
negatively affected.
Inappropriately long period
of non-use (standstill).
Draw off water for a few
minutes.
Change the filter cartridge.
Solids in the filtered water.
Inappropriately high flow
rate through the filter.
Check the filter elements
for damage or leaks.
Filter cartridge damaged or
not properly installed.
Check the installation and
change it if necessary.
Water loss from the
system.
Faulty joint.
Check the O-rings and
seals for deformation or
wear.
Check the filter housing for
damage.
Have the filter housing
replaced by the specialist
installer.