Revision A5 3-24
GRT Avionics HXr Installation Manual
Volume level will be controlled by menu settings within the display unit. (NOTE: This option is not
yet available, but Pin B24 has been reserved for it.)
3.10 Trim and Flap Servos and Sensors
Flap & trim position indicators may be displayed on the EFIS screen using the analog inputs. Pull-up
resistors for these sensors are provided internally in the HX and HXr systems; if used, they must
be turned on in the Setup Menu. Use Trim/Flap Sensor Installation wiring diagram & notes in the
Appendix of this manual for wiring and setup guidance.