8
Automated Roll-Up Sides
Revision date: 12.16.20
Attach Motor to Adapter
ATTACH MOTOR TO ADAPTER
Complete these steps:
1. Insert the shear pin bushing into the mounting hole of the motor output
shaft and hold in place.
2. Using a 1-1/2" long hex drive screw (117109) and one 3/16" locknut
(117095), attach the motor adaptor to the motor output shaft.
Verify shear
pin bushing remained in place and did not fall out.
3. Tighten the hex bolt using a 10mm socket and ratchet and a 4mm hex
wrench (or hex bit).
4. Reattach the anti-billow ropes or adjust if these were loosened or
removed to install the automated roll-up panel components.
5. Repeat the previous procedures to install the remaining roll-up side
components for the other roll-up panel.
6. After installing the components for both roll-up panels, continue with the
procedure on the next page.
Gather parts:
• Shear Pin Bushing (117058)
• 1-1/2" Hex Drive Screw (117109)
• Nylock Hex Locknut (117095)
STEP 1
STEP 3
STEP 2