background image

S

mart

P

anel 

Hardware

 

40 

DVS

 

63067 V2.0 

© 2011 by Grossenbacher Systeme AG

 

 
 
 

DVS 63067-V3.0

Summary of Contents for SmartPanel SP-240

Page 1: ...AG Spinnereistrasse 10 CH 9008 St Gallen Phone 41 0 71 243 29 29 Fax 41 0 71 243 29 28 info gesys ch www gesys ch Grossenbacher Systeme GmbH Ruhrstrasse 15 DE 63452 Hanau Phone 49 0 6181 6751 999 Fax...

Page 2: ...any distribution to third parties can only be made with the express permission of Grossenbacher Systeme AG Grossenbacher Systeme AG does not accept any liability for damages arising from the use of a...

Page 3: ...device must not be switched on when it is covered with condensation When changing its location from cold to warm allow the device to acclimatize to the new conditions before commissioning No warranty...

Page 4: ...afety instructions given in this device description or on the product itself are persons who as engineering personnel are either familiar with the safety concepts of automation or as operating personn...

Page 5: ...M1 serial interface 19 5 10 CAN interface 19 5 11 Inserting Removing the Micro SDCARD 22 5 12 Temperature sensor connector 22 6 Operation 23 6 1 Startup Shutdown behaviour 23 7 Mounting instructions 2...

Page 6: ...SmartPanel Hardware 6 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 7: ...ted safety measures are not implemented The individual Warning pictograms have the following meaning Caution General An instruction to be observed in order to ensure protection against hazards and the...

Page 8: ...SmartPanel Hardware 8 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 9: ...luding integrated TargetVisu and WebVisu Without moving parts the devices are at home in rugged environment The seamless resistive touch screen provides a fast intuitive and ergonomic operation Unique...

Page 10: ...SmartPanel Hardware 10 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 11: ...oard NAND Flash MicroSD Slot Interfaces 1 x Ethernet 2 x USB Master 1 x RS232 485 422 1 x CAN Stromversorgung 24VDC SP 240 03R 000 Ord No 50 81 862 SmartPanel 3 5 TFT 320x240 64k colours Resistive Tou...

Page 12: ...EPAM RTS and Codesys RTS V2 3 preinstalled on Onboard Flash Ord No 5055030 RTS HMI ThinClient SPi25 WindowsCE6 Professional ThinClient preinstalled on Onboard Flash Ord No 5055033 RTS HMI open NET SPi...

Page 13: ...Onboard Flash Type 128MB NAND Flash Memory SDRAM MB 64MB Retain memory kB 256kB1 Exchangeable memory Micro SDCARD Memorystick Type Micro SD Card Slot or Memorystick optional via USB Interfaces COM1 T...

Page 14: ...SmartPanel Hardware 14 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 15: ...Panel devices belongs to protection class 3 The system power supply must be provided with a 24VDC SELV voltage Section 11 The power supply is NOT isolated The GND connection is directly connected to t...

Page 16: ...f the COM1 interface the fault current flows via this 0V connection If the housing is not lying well set on the 0V potential the result can be destruction of the device or of the external components F...

Page 17: ...eld braid by approx 3 cm 3 Turn back the braid over the cable sheath 4 Use a heat shrinkable tubing or rubber grommet to cover the exposed cable sheath with the folded back shield braid so that 5 to 8...

Page 18: ...nection to HUB or to another device Green ACT sending or receiving Cables connected to the Ethernet must be laid separately from the low voltage cables To ensure disturbance free operation it is stron...

Page 19: ...be laid separately from the low voltage cables To ensure disturbance free operation it is strongly recommended to use cables with shield The COM1 interface can be configured as RS232 485 or 422 In ca...

Page 20: ...iption of the wiring is provided in the Codesys Soft PLC system description Wiring instructions The stations on the bus system are connected via fieldbus lines complying with ISO 11898 The cables must...

Page 21: ...ND are both connected internally with the CAN Ground Pins 4 5 and 8 must not be connected The CAN bus driver is fed internally Baud rate and cable lengths Baud rate Max length 20kBit sec 2500m 25kBit...

Page 22: ...rage devices s a accessories Micro SDCARDs may be removed during operation To avoid data loss it is recommended to use the operating system functionality to replace the removeable devices s a system d...

Page 23: ...oad current supply transformers etc must be ensured Avoid the exposure of the flat screen to direct sunlight The radiation from the sun UV component reduces the lifespan of the LCD display The followi...

Page 24: ...Panel Hardware 24 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG 7 3 FRONT PANEL CUTOUT 3 5 TO 7 Tolerance for panel cutout 0 0 5 mm The thickness of the front panel must not exceed 2 5 mm DVS 63067...

Page 25: ...SmartPanel Hardware 2011 by Grossenbacher Systeme AG DVS 63067 V2 0 25 7 4 MECHANICAL DIMENSIONS FRONTSIDE 3 5 TO 7 Dimensions 3 5 DVS 63067 V3 0...

Page 26: ...SmartPanel Hardware 26 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG Dimensions 4 3 IR DVS 63067 V3 0...

Page 27: ...SmartPanel Hardware 2011 by Grossenbacher Systeme AG DVS 63067 V2 0 27 Dimensions 5 7 DVS 63067 V3 0...

Page 28: ...SmartPanel Hardware 28 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG Dimensions 7 DVS 63067 V3 0...

Page 29: ...n by the touch controller This initiates an operation if a touch activated screen element was touched e g a button Because of this function principle the resistive touch screen has to be calibrated Th...

Page 30: ...SmartPanel Hardware 30 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 31: ...ic options are available Symptom Possible cause and solution Device does not start screen dark or error messages during startup Check power supply fuse faulty Date time incorrect device was not powere...

Page 32: ...SmartPanel Hardware 32 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 33: ...of the screen will not accidentally initiate functions Please use a soft cloth to ensure that the surface is not scratched or scoured Do not use solvents Repairs Repairs to the SmartPanels should only...

Page 34: ...SmartPanel Hardware 34 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 35: ...eyboard mouse Resolution Resistive touch screen 12 Bit analog 0 4096 for all display sizes Keyboard Mouse Via USB Ambient conditions Operating climate Class 3K3 EN50178 advanced reduced 0 60 C vertica...

Page 36: ...reverse polarity Yes 5 2 Fuse protection Yes Potential isolation No Current consumption 3 5 Idle without USB load 4 3 5 7 7 4W 4W 5W 6W CPU Type ARM9 iMX25 400MHz Memory Type 64MB soldered Realtime c...

Page 37: ...rtPanel devices that are no longer used must be disposed of properly or returned to the manufacturer for disposal manufacturer s address Section 13 Materials Housing Galvanized sheet steel Front frame...

Page 38: ...SmartPanel Hardware 38 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 39: ...89 336 EEC The generic standards below were used to assess the electromagnetic compatibility of the SmartPanel EN 61000 6 3 Emission EN 61000 6 2 Immunity The following standard was used to assess th...

Page 40: ...SmartPanel Hardware 40 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 41: ...11 Fis P 19 COM1 discription changed Manufacturer address Grossenbacher Systeme AG Spinnereistrasse 10 CH 9008 St Gallen Switzerland Tel 41 0 71 243 29 29 Fax 41 0 71 243 29 28 Email info gesys ch Hom...

Page 42: ...SmartPanel Hardware 42 DVS 63067 V2 0 2011 by Grossenbacher Systeme AG DVS 63067 V3 0...

Page 43: ...panel cutout 25 Fuse 16 Fuse protection 38 I Inserting Removing the Micro SDCARD 22 Introduction 9 K Keyboard 13 M Maintenance and repair 35 Manufacturer 41 Manufacturer address 43 mass storage 13 Mec...

Page 44: ...DVS 63067 V3 0...

Reviews: