![Grohe Minta 32 917 Manual Download Page 5](http://html1.mh-extra.com/html/grohe/minta-32-917/minta-32-917_manual_2268899005.webp)
2
GB
Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters. Operation with low-pressure
displacement water heaters is
not
possible.
Specifications
•
Flow pressure
min. 0.5 bar
recommended 1 - 5 bar
•
Operating pressure
max. 10 bar
•
Test pressure
16 bar
If static pressure is greater than 5 bar, fit pressure
reducer.
Avoid major pressure differences between hot and
cold water supply.
•
Flow rate at 3 bar flow pressure
approx. 11.5 l/min
•
Temperature
Hot water inlet:
(maximum) 80 °C
Recommended:
(energy saving) 60 °C
•
Water connection
cold - right
hot - left
•
Max. clamping length
max. 60mm
Installation
Flush pipes thoroughly!
Prepare sink mixer
Refer to the dimensional drawing on fold-out page I.
Fit swivel spout
Swivel range can be adjusted by means of stop (A),
see fold-out page III, Fig. [1].
Install sink mixer,
see Fig. [2].
Note:
If the support plate (B) is omitted, the clamping
length can be increased by 15mm.
The following lever positions can also be obtained,
see Fig. [3].
Connect sink mixer,
see Figs. [2] and [4].
- Hot-water connection (marked red)
= left
- Cold-water connection (marked blue)
= right
Open cold and hot-water supply and check
connections for leakage!
Operation
(Lever head position right)
Slide lever to right
= open (water flow)
Slide lever to left
= close
Slide lever towards front
= cold water
Slide lever towards back
= hot water
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see “replacing the cartridge”
point 1 to 3, Figs. [5] and [6].
Maintenance
Inspect and clean all parts, replace as necessary and
grease with Grohe special grease (order no. 18 012).
Shut off cold and hot water supply!
I. Replacing the cartridge,
see Fig. [5].
1. Lever out plug (C).
2. Remove screw (D) and pull off lever (E).
3. Unscrew cap (G).
4. Remove screws (H) and detach complete
cartridge (J).
5. Replace complete cartridge (J).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the
grooves on the housing. Fit screws (H) and tighten
evenly and alternately
.
II.
Unscrew and clean
aerator (13 928)
, see fold-out
page II.
Assemble in reverse order.
Replacement parts,
see fold-out page II
( * = special accessories).
Care
For directions on the care of this fitting, please refer to
the accompanying Care Instructions.