Installation Type #1 and Type #2

Attention for type #1

If 

both

 rough-in outlets are used, you have to install a spout 

with

 

diverter

. If only 

the lower

 rough-in outlet is used, you 

have to install a spout 

without

 

diverter

.

Installation

1. Install control unit and secure with screws, see Fig. [5].
2. Close water flow by turning the yoke. The mark (A) must be 

on top, see Fig. [6].

3. Open the hot and cold integrated service stops, see Fig. [6].
4. While installation observe the right mounting position.
5. For installation of handle parts after adjustment, see Figs. [7] 

and [8].

If the thermostat has been installed at too great a depth,

 

this can be adjusted by 27mm or 1 1/16“ with an extension set 
(see Page II, ref. No. 47 822).

Adjustment

Temperature setting,

 see Fig. [9].

• Before the mixer is put into service, if the mixed water 

temperature measured at the point of discharge varies from 
the specified temperature set on the thermostat handle.

• After any maintenance operation on the thermostatic 

cartridge.

Valve is closed with lever (B) in vertical position:

Open volume control by turning the lever (B).

1. Measure the temperature of the water emerging with a 

thermometer.

2. Turn regulation nut (C) until the water emerging has reached 

a temperature of 38 °C or 100 °F.

Reversed union 

(hot on right - cold on left). Replace 

thermostatic cartridge, special cartridge for service is:

Ref. No.: 47 175 (1/2").

5

6

A

8

9

38 °C

100 °F

C

B

7

Summary of Contents for 19 822

Page 1: ...UAE 12 TR 17 EST 22 UA 27 F 3 DK 8 GR 13 SK 18 LV 23 RUS 28 E 4 N 9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com 19 839 19 822 19 825 99 790 031 M 2193...

Page 2: ...ette instruction l utilisateur de la robinetterie Entregue estas instrucciones al usario final de la grifer a Please pass these instructions on to the end user of the fitting I Type 1 19 822 Type 2 19...

Page 3: ...II II Type 1 19 822 Type 2 19 825...

Page 4: ...tions on to the end user of the faucet without bypass use with use of integrated Thermostat trim type 1 single use bypass Thermostat trim type 2 integrated two way diverter Installation options with d...

Page 5: ...separate volume controls required Thermostat trim type 3 high flow Installation options with different types of trims 2...

Page 6: ...5 psi greater than 5 bar or 72 5 psi fit pressure reducing valve Max operating pressure 8 5 bar or 125 psi Max test pressure 34 5 bar or 500 psi Flow rates at 3 bar or 45 psi Type 1 19 822 and Type 2...

Page 7: ...led at too great a depth this can be adjusted by 27mm or 1 1 16 with an extension set see Page II ref No 47 822 Adjustment Temperature setting see Fig 9 Before the mixer is put into service if the mix...

Page 8: ...discharge varies from the specified temperature set on the thermostat handle After any maintenance operation on the thermostatic cartridge One or more separate volume controls D not supplied are requi...

Page 9: ...ever F left or right Select hot or cold water flow Turn lever B to the right Open water outlet as pipeline installation is prepared If a spout with diverter is installed outlet to bath and shower is p...

Page 10: ...is to be removed from the rough in for servicing first close the inlet stops then open the flow control to allow any internal pressure to be released from within the unit Inspect and clean all parts...

Reviews: