background image

OM-GSSP-BL-G BOILERLESS STEAMER

MM/DD/YY

Set Date

English

Language

°F

Temp 

Indication

On

3

Number

of Timers

On

Compensating

Timers

On

Timer Screen

Lock

Off

12:00pm

Settings

2 min

Door Alarm

4

Brightness

Mid

Alarm Volume

On

Delime Button

Delime Reminder

Keyboard Beep

HH:MM

Set Clock

12 hr

Time Format

Contact Us

Service

Settings

Unit Info

12:00pm

Menu

Contact Us

Service

Settings

Unit Info

12:00pm

Menu

MM/DD/YY

Set Date

English

Language

°F

Temp 

Indication

On

3

Number

of Timers

On

Compensating

Timers

On

Timer Screen

Lock

Off

12:00pm

Settings

2 min

Door Alarm

4

Brightness

Mid

Alarm Volume

On

Delime Button

Delime Reminder

Keyboard Beep

HH:MM

Set Clock

12 hr

Time Format

12:00pm

Performing self-diagnostic

Delime

DELIME button is only displayed during startup if the DELIME button is turned to 
ON in settings menu.  The default setting for DELIME button is OFF.  The DELIME 
REMINDER will provide you status visuals of where you are in the deliming 
schedule.  When the reminder is ON, the DELIME button will do the following:

  When 75% of the delime schedule has been reached, the DELIME button will 

turn yellow

  When 90% of the delime schedule has been reached, the DELIME button will 

turn yellow

  Upon expiration of the DELIME schedule, the DELIME button will turn red

  the DELIME button will return to normal after deliming has been completed or 

the reminder is reset

12:00pm

Delime 

Prepare Cavity

Remove Fan Shroud, Racks 

and Steam lid. Please wait 

a few minutes to allow 

reservoir to fill with water. 

     

WARNING

Hot Surfaces. Exercise caution 

when removing hot components.

12:00pm

Delime 

In Progress

Delime process has 

begun. Process will take 

approximately 60-90 

minutes to complete.

Continue

12:00pm

Delime 

Add Solution

Using caution, add specified 

amount of approved 

Deliming Solution into 

water reservoir. Close door 

and press continue.

     

WARNING

Hot Surfaces. Exercise caution when 

touching interior compartment.

Restart

12:00pm

Delime 

Complete

Allow unit to cool prior to 

wiping out interior. Clean all 

probes, steam lid, drip cup 

and overflow drains. Replace 

interior components. Press 

restart to use the steamer or 

push the Power Button to 

turn off the unit.

     

WARNING

Hot Surfaces. Exercise caution when 

touching interior compartment.

Start

Reminder Reset

12:00pm

Delime 

Process Note

Prior to starting the 

Delime process, review the 

Operator's manual for 

detailed instructions and 

warnings.

Press DELIME and follow instruction displayed on the unit (shown above) for the 
delime procedure. Delime process takes approximately 60-90 minutes. Once 
complete the unit will restart and go through the start up diagnostic sequence.

CUP & OVERFLOW DRAINS

1.  Turn your unit off and allow it to completely drain.  Units will drain automatically 

when the units are powered off. This is a 5 minute process.

2.  Once the reservoir has completely drained (approximately 5 minutes), stand 

to the hinged side of the door and slowly open the door, allowing all of the 
steam to escape from the cavity. Allow the cavity to completely cool down 
and confirm that the reservoir has completely emptied before cleaning the 
overflow drain.

3.  Remove the steam lid (image below left) and fan cover assembly (image below 

right), prior to cleaning the overflow drain.

 
4.  Insert the cleaning brush into the cup and overflow drains located at the lower, 

middle, and back right side of your steamer’s cavity (image below).  As the 
brush is pushed through the cup and overflow draina, it will bend to follow 
the shape of the drain as it travels the length of the cup and overflow draina.  
Once you use the cleaning brush for the first time, the wire between the handle 
and the bristles will retain a curved shape after the brush is removed from the 
cup and overflow drains.  The brush is designed to bend/curve in this fashion.  
There is no need to straighten the wire between cleaning/usage.  

5.  With the cleaning brush, push and pull through the entire lengthy of the 

overflow drain several times.  The brush should be inserted at least ten inches 
(10) into the overflow drain to pass through the entire length of the drain 
piping.  Repeat as necessary until the overflow drain is clean.  Ensure that the 
overflow drain works properly by pouring or squirting water into the cup and 
overflow drains and confirming that the water is flowing freely into the drain 
receptacle and not being blocked and backing up into the steamer cavity.

 

If the cup and overflow drains is clogged such that the cleaning brush will 
not clear the blockage or if water cannot move through the cup and overflow 
drains into the drain receptacle without backing up into the steamer cavity, 
then a service call needs to be made and all use of the steamer must be 
discontinued until the service agent evaluates the issue and confirms that the 
unit is ready for further operation.

 
6.  Clean the steaming cavity per the cleaning instructions in your operators’ 

manual.

7.  Re-install the steam lid and fan cover assembly.
8.  Leave the door open to prolong the life of the door gasket and to allow the 

cavity to air out.

9.  Clean, dry and store the overflow cleaning brush after each use.
10.  If a replacement brush is needed, the part number is 175977.

MAINTENANCE

The Boilerless Steamer is designed for minimum maintenance and no user 
adjustments should be necessary. Certain parts may need replacement after 
prolonged use. If there is a need for service, only Groen Authorized Service Agents 
should perform the work.
If steam or condensate is seen leaking from around the door, take the following steps:
1.   Check the door gasket. Replace it if it is cracked or split.
2.   Inspect the steaming chamber drain to be sure it is not blocked.
3.   Adjust the door latch pin to allow for changes that might occur as the gasket ages.

a.   Loosen the lock nut at the base of the latch pin, then turn the latch pin 1/4 

turn clockwise, and tighten the lock nut.

b.   After adjustment, run the unit to test for further steam leakage.
c.   If there is still leakage, repeat the adjustment
d.   Continue adjusting the pin clockwise until the door fits tightly enough to 

prevent leakage. The hinge may also be adjusted.

REPLACEMENT PARTS

 

To order parts, contact your Authorized Service Agent. Supply the model 
designation, serial number, part description, part number, quantity, and when 
applicable, voltage and phase.

CONTACT US

If you have questions pertaining to the content in this manual, contact Unified 
Brands at 888-994-7636 or [email protected].

Summary of Contents for SMARTSTEAM GSSP-BL-10GS

Page 1: ...cy Massachusetts 02169 7471 NFPA 54 National Fuel Gas Code NFPA 70 National Electrical Code NSF INTERNATIONAL 789 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48105 9723 888 994 7636 fax 888 864 7636 unifiedbrands net The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this d...

Page 2: ...S A BRAISING PAN DEEP FAT FRYER CHARBROILER OR KETTLE TO AVOID DRAINAGE PROBLEMS LEVEL THE UNIT FRONT TO BACK AND PITCH SLIGHTLY TO THE FRONT INSTALLATION Minimum Clearances Boilerless Steamer requires the following minimum clearances to any surface combustible or noncombustible Right Side 2 inches Left Side 2 inches Rear 6 inches WARNING ALLOW STEAMING CHAMBER TO COOL COMPLETELY BEFORE CLEANING W...

Page 3: ...vable gas appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the standard for quick disconnect devices for use with gas fuel ANSI Z21 41 CSA 6 9 2 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement 3 The location where the res...

Page 4: ...1 Dual Water Connections The same water supply connection is used for both units At the water inlet valve a 3 4 inch female NH connector garden hose type is used for the water supply 2 Electrical Supply Connection Separate electrical connections will be required for each steamer to be stacked Each steamer unit must have it s own branch circuit protection 3 Gas Connection A single gas connection is...

Page 5: ...erature of the steam lid causing the protein drippings from the shellfish to foam To avoid this place a catch pan on the lowest level to prevent the drippings from coming into contact with the steam lid TIMED MODE 12 00pm Timed Manual Hold SHUTDOWN H MM SS 12 00pm HH MM Start 2 3 1 5 6 4 7 9 0 8 Set Cook Time Hold Pan Timers 12 00pm 1m 1 12 12 00pm Timed 1m Pan Timers 45 20 The TIMED mode allows y...

Page 6: ...STEAMER AS SPECIFIED COULD NEGATIVELY IMPACT THE PERFORMANCE OF THE STEAMER OR WILL NOT ALLOW UNIT TO HEAT To keep your Boilerless Steamer in proper working condition use the following daily procedure to clean the unit This regular manual cleaning will reduce the time and effort required to clean the water reservoir and cavity SUGGESTED SUPPLIES 1 Mild detergent 2 Stainless steel exterior cleaner ...

Page 7: ... right prior to cleaning the overflow drain 4 Insert the cleaning brush into the cup and overflow drains located at the lower middle and back right side of your steamer s cavity image below As the brush is pushed through the cup and overflow draina it will bend to follow the shape of the drain as it travels the length of the cup and overflow draina Once you use the cleaning brush for the first tim...

Page 8: ...DE ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE In no event shall UNIFIED BRANDS be liable for damages or delay or for any consequential special or contingent damages arising out of any breach of our warranty whether or not we have know...

Page 9: ...9 OM GSSP BL G BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Reviews: