7
OM-GSSP-BL-G BOILERLESS STEAMER
MM/DD/YY
Set Date
English
Language
°F
Temp
Indication
On
3
Number
of Timers
On
Compensating
Timers
On
Timer Screen
Lock
Off
12:00pm
Settings
2 min
Door Alarm
4
Brightness
Mid
Alarm Volume
On
Delime Button
Delime Reminder
Keyboard Beep
HH:MM
Set Clock
12 hr
Time Format
Contact Us
Service
Settings
Unit Info
12:00pm
Menu
Contact Us
Service
Settings
Unit Info
12:00pm
Menu
MM/DD/YY
Set Date
English
Language
°F
Temp
Indication
On
3
Number
of Timers
On
Compensating
Timers
On
Timer Screen
Lock
Off
12:00pm
Settings
2 min
Door Alarm
4
Brightness
Mid
Alarm Volume
On
Delime Button
Delime Reminder
Keyboard Beep
HH:MM
Set Clock
12 hr
Time Format
12:00pm
Performing self-diagnostic
Delime
DELIME button is only displayed during startup if the DELIME button is turned to
ON in settings menu. The default setting for DELIME button is OFF. The DELIME
REMINDER will provide you status visuals of where you are in the deliming
schedule. When the reminder is ON, the DELIME button will do the following:
•
When 75% of the delime schedule has been reached, the DELIME button will
turn yellow
•
When 90% of the delime schedule has been reached, the DELIME button will
turn yellow
•
Upon expiration of the DELIME schedule, the DELIME button will turn red
•
the DELIME button will return to normal after deliming has been completed or
the reminder is reset
12:00pm
Delime
Prepare Cavity
Remove Fan Shroud, Racks
and Steam lid. Please wait
a few minutes to allow
reservoir to fill with water.
WARNING
Hot Surfaces. Exercise caution
when removing hot components.
12:00pm
Delime
In Progress
Delime process has
begun. Process will take
approximately 60-90
minutes to complete.
Continue
12:00pm
Delime
Add Solution
Using caution, add specified
amount of approved
Deliming Solution into
water reservoir. Close door
and press continue.
WARNING
Hot Surfaces. Exercise caution when
touching interior compartment.
Restart
12:00pm
Delime
Complete
Allow unit to cool prior to
wiping out interior. Clean all
probes, steam lid, drip cup
and overflow drains. Replace
interior components. Press
restart to use the steamer or
push the Power Button to
turn off the unit.
WARNING
Hot Surfaces. Exercise caution when
touching interior compartment.
Start
Reminder Reset
12:00pm
Delime
Process Note
Prior to starting the
Delime process, review the
Operator's manual for
detailed instructions and
warnings.
Press DELIME and follow instruction displayed on the unit (shown above) for the
delime procedure. Delime process takes approximately 60-90 minutes. Once
complete the unit will restart and go through the start up diagnostic sequence.
CUP & OVERFLOW DRAINS
1. Turn your unit off and allow it to completely drain. Units will drain automatically
when the units are powered off. This is a 5 minute process.
2. Once the reservoir has completely drained (approximately 5 minutes), stand
to the hinged side of the door and slowly open the door, allowing all of the
steam to escape from the cavity. Allow the cavity to completely cool down
and confirm that the reservoir has completely emptied before cleaning the
overflow drain.
3. Remove the steam lid (image below left) and fan cover assembly (image below
right), prior to cleaning the overflow drain.
4. Insert the cleaning brush into the cup and overflow drains located at the lower,
middle, and back right side of your steamer’s cavity (image below). As the
brush is pushed through the cup and overflow draina, it will bend to follow
the shape of the drain as it travels the length of the cup and overflow draina.
Once you use the cleaning brush for the first time, the wire between the handle
and the bristles will retain a curved shape after the brush is removed from the
cup and overflow drains. The brush is designed to bend/curve in this fashion.
There is no need to straighten the wire between cleaning/usage.
5. With the cleaning brush, push and pull through the entire lengthy of the
overflow drain several times. The brush should be inserted at least ten inches
(10) into the overflow drain to pass through the entire length of the drain
piping. Repeat as necessary until the overflow drain is clean. Ensure that the
overflow drain works properly by pouring or squirting water into the cup and
overflow drains and confirming that the water is flowing freely into the drain
receptacle and not being blocked and backing up into the steamer cavity.
If the cup and overflow drains is clogged such that the cleaning brush will
not clear the blockage or if water cannot move through the cup and overflow
drains into the drain receptacle without backing up into the steamer cavity,
then a service call needs to be made and all use of the steamer must be
discontinued until the service agent evaluates the issue and confirms that the
unit is ready for further operation.
6. Clean the steaming cavity per the cleaning instructions in your operators’
manual.
7. Re-install the steam lid and fan cover assembly.
8. Leave the door open to prolong the life of the door gasket and to allow the
cavity to air out.
9. Clean, dry and store the overflow cleaning brush after each use.
10. If a replacement brush is needed, the part number is 175977.
MAINTENANCE
The Boilerless Steamer is designed for minimum maintenance and no user
adjustments should be necessary. Certain parts may need replacement after
prolonged use. If there is a need for service, only Groen Authorized Service Agents
should perform the work.
If steam or condensate is seen leaking from around the door, take the following steps:
1. Check the door gasket. Replace it if it is cracked or split.
2. Inspect the steaming chamber drain to be sure it is not blocked.
3. Adjust the door latch pin to allow for changes that might occur as the gasket ages.
a. Loosen the lock nut at the base of the latch pin, then turn the latch pin 1/4
turn clockwise, and tighten the lock nut.
b. After adjustment, run the unit to test for further steam leakage.
c. If there is still leakage, repeat the adjustment
d. Continue adjusting the pin clockwise until the door fits tightly enough to
prevent leakage. The hinge may also be adjusted.
REPLACEMENT PARTS
To order parts, contact your Authorized Service Agent. Supply the model
designation, serial number, part description, part number, quantity, and when
applicable, voltage and phase.
CONTACT US
If you have questions pertaining to the content in this manual, contact Unified
Brands at 888-994-7636 or [email protected].