background image

OM-GSSP-BL-G BOILERLESS STEAMER

6.   Upon completion of self diagnostics, the screen will transition to the manual 

cook screen and the unit will begin pre-heating. If exited, the screen will 
transition to the home screen where it will continue to pre-heat. 

 

Manual

Pan Timers

12:00pm

Heating

In Progress

SHUTDOWN H:MM:SS

  

Pre-heating

12:00pm

Timed

Manual

Hold

7.   On initial start up, the installer needs to record the startup date in the controls.  

Go into the MENU

à

SERVICE

à

STARTUP DATE, and enter the date.  After this 

date is set, it cannot be changed. To exit this menu, hit the back arrow until you 
return to the home screen.

SHUT-DOWN

1.  To shut down the unit, press the power button on the front control panel. The 

steam generating reservoir will then fill with cold water and drain. You will see 
a shutdown progress bar on the display.

 

NOTE: For operation at high altitudes (2000 feet and 
above), please consult the Groen Foodservice Engineering 
Department. This must be specified at time of order.

Shutdown in process, 

please wait

Time for a break? 

You deserve it! 

I'll see you 

tomorrow.

USER SETTINGS

SYMBOL GUIDE

 

Temperature Ready

 This symbol is green and is found in the upper left 

corner of your screen. It is visible when the unit has reached temperature.

 

Door Open

 This symbol is orange and is found in the upper left corner of 

your screen. It is displayed when the door is open.

 

Menu

 This menu option is found in the upper right corner of your display 

and is accessible from most screens. This is how you access all settings 
and user information.

 

Back Button

 This button is displayed in the upper right corner of your 

screen and is used to return to a previous screen or menu.

 

Scroll Button 

These buttons are displayed when options can not fit on 

your screen. Press appropriate button to scroll up or scroll down to access 
further options.

 

Exit Button 

Any image with an X communicates an exit option.

 

+1m Button

 This button is found on steamer timer pages and allows you 

to quickly add 1 minutes to the steam time.

1.   Dual Water Connections
 

The same water supply connection is used for both units. At the water inlet 
valve a 3/4 inch female NH connector (garden hose type) is used for the water 
supply.

2.   Electrical Supply Connection
  Separate electrical connections will be required for each steamer to be 

stacked. Each steamer unit must have it’s own branch circuit protection.

3.   Gas Connection
 

A single gas connection is required for both steamers. Gas supply must be 
adequate under all conditions as listed on page 2.

4.   Drain Connection
 

Steamers must be leveled front to back, and pitched to the front (maximum 
1/4 inch) by adjusting the bullet feet on the cabinet or stand base.

 

For all factory-stacked GSSP-BL steamers, a 2-1/2 inch ID hose is attached to 
the unit drain. It must be rated for boiling water.

COUNTER-MOUNTED UNITS

WARNING:  DO NOT STACK GSSP-BL STEAMERS WHEN LEGS ARE USED.

This section is applicable if the steamer will be mounted to a counter. All four edges 
of the bottom of the steamer must be sealed with RTV to the counter if the 4 inch 
legs are not used. Counter must be made of a noncombustible material such as 
metal or tile.

INITIAL START-UP

WARNING:  WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF 

THE UNIT. STEAM CAN CAUSE BURNS.

START-UP

After the Boilerless Steamer has been installed, test it to ensure that the unit is 
operating correctly. 
1.   Remove all literature and packing materials from the interior and exterior of 

the unit.

2.   Make sure the water supply line is open.
3.   Turn on electrical service to the unit. The steamer will not operate without 

electrical power. Do not attempt to operate the unit during a power failure.

 

NOTE: The door MUST be closed for the burner to work.

4.   There is an on/off switch in the rear of the unit.  Confirm that is it in the ON 

position.  

5.  To turn the unit on, press the power button on the front control panel. The 

power button will light up and the touch screen will display that the unit is 
going through self diagnostics.

 

NOTE: DELIME button is only displayed 
during startup if the DELIME button is 
turned to ON in settings menu.  The 
default setting for DELIME button is OFF.

12:00pm

Performing self-diagnostic

12:00pm

Performing self-diagnostic

Delime

+1m

Summary of Contents for SMARTSTEAM GSSP-BL-10GS

Page 1: ...cy Massachusetts 02169 7471 NFPA 54 National Fuel Gas Code NFPA 70 National Electrical Code NSF INTERNATIONAL 789 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48105 9723 888 994 7636 fax 888 864 7636 unifiedbrands net The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this d...

Page 2: ...S A BRAISING PAN DEEP FAT FRYER CHARBROILER OR KETTLE TO AVOID DRAINAGE PROBLEMS LEVEL THE UNIT FRONT TO BACK AND PITCH SLIGHTLY TO THE FRONT INSTALLATION Minimum Clearances Boilerless Steamer requires the following minimum clearances to any surface combustible or noncombustible Right Side 2 inches Left Side 2 inches Rear 6 inches WARNING ALLOW STEAMING CHAMBER TO COOL COMPLETELY BEFORE CLEANING W...

Page 3: ...vable gas appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the standard for quick disconnect devices for use with gas fuel ANSI Z21 41 CSA 6 9 2 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement 3 The location where the res...

Page 4: ...1 Dual Water Connections The same water supply connection is used for both units At the water inlet valve a 3 4 inch female NH connector garden hose type is used for the water supply 2 Electrical Supply Connection Separate electrical connections will be required for each steamer to be stacked Each steamer unit must have it s own branch circuit protection 3 Gas Connection A single gas connection is...

Page 5: ...erature of the steam lid causing the protein drippings from the shellfish to foam To avoid this place a catch pan on the lowest level to prevent the drippings from coming into contact with the steam lid TIMED MODE 12 00pm Timed Manual Hold SHUTDOWN H MM SS 12 00pm HH MM Start 2 3 1 5 6 4 7 9 0 8 Set Cook Time Hold Pan Timers 12 00pm 1m 1 12 12 00pm Timed 1m Pan Timers 45 20 The TIMED mode allows y...

Page 6: ...STEAMER AS SPECIFIED COULD NEGATIVELY IMPACT THE PERFORMANCE OF THE STEAMER OR WILL NOT ALLOW UNIT TO HEAT To keep your Boilerless Steamer in proper working condition use the following daily procedure to clean the unit This regular manual cleaning will reduce the time and effort required to clean the water reservoir and cavity SUGGESTED SUPPLIES 1 Mild detergent 2 Stainless steel exterior cleaner ...

Page 7: ... right prior to cleaning the overflow drain 4 Insert the cleaning brush into the cup and overflow drains located at the lower middle and back right side of your steamer s cavity image below As the brush is pushed through the cup and overflow draina it will bend to follow the shape of the drain as it travels the length of the cup and overflow draina Once you use the cleaning brush for the first tim...

Page 8: ...DE ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE In no event shall UNIFIED BRANDS be liable for damages or delay or for any consequential special or contingent damages arising out of any breach of our warranty whether or not we have know...

Page 9: ...9 OM GSSP BL G BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...