4
OM-GSSP-BL-G BOILERLESS STEAMER
6. Upon completion of self diagnostics, the screen will transition to the manual
cook screen and the unit will begin pre-heating. If exited, the screen will
transition to the home screen where it will continue to pre-heat.
Manual
Pan Timers
12:00pm
Heating
In Progress
SHUTDOWN H:MM:SS
Pre-heating
12:00pm
Timed
Manual
Hold
7. On initial start up, the installer needs to record the startup date in the controls.
Go into the MENU
à
SERVICE
à
STARTUP DATE, and enter the date. After this
date is set, it cannot be changed. To exit this menu, hit the back arrow until you
return to the home screen.
SHUT-DOWN
1. To shut down the unit, press the power button on the front control panel. The
steam generating reservoir will then fill with cold water and drain. You will see
a shutdown progress bar on the display.
NOTE: For operation at high altitudes (2000 feet and
above), please consult the Groen Foodservice Engineering
Department. This must be specified at time of order.
Shutdown in process,
please wait
Time for a break?
You deserve it!
I'll see you
tomorrow.
USER SETTINGS
SYMBOL GUIDE
Temperature Ready
This symbol is green and is found in the upper left
corner of your screen. It is visible when the unit has reached temperature.
Door Open
This symbol is orange and is found in the upper left corner of
your screen. It is displayed when the door is open.
Menu
This menu option is found in the upper right corner of your display
and is accessible from most screens. This is how you access all settings
and user information.
Back Button
This button is displayed in the upper right corner of your
screen and is used to return to a previous screen or menu.
Scroll Button
These buttons are displayed when options can not fit on
your screen. Press appropriate button to scroll up or scroll down to access
further options.
Exit Button
Any image with an X communicates an exit option.
+1m Button
This button is found on steamer timer pages and allows you
to quickly add 1 minutes to the steam time.
1. Dual Water Connections
The same water supply connection is used for both units. At the water inlet
valve a 3/4 inch female NH connector (garden hose type) is used for the water
supply.
2. Electrical Supply Connection
Separate electrical connections will be required for each steamer to be
stacked. Each steamer unit must have it’s own branch circuit protection.
3. Gas Connection
A single gas connection is required for both steamers. Gas supply must be
adequate under all conditions as listed on page 2.
4. Drain Connection
Steamers must be leveled front to back, and pitched to the front (maximum
1/4 inch) by adjusting the bullet feet on the cabinet or stand base.
For all factory-stacked GSSP-BL steamers, a 2-1/2 inch ID hose is attached to
the unit drain. It must be rated for boiling water.
COUNTER-MOUNTED UNITS
WARNING: DO NOT STACK GSSP-BL STEAMERS WHEN LEGS ARE USED.
This section is applicable if the steamer will be mounted to a counter. All four edges
of the bottom of the steamer must be sealed with RTV to the counter if the 4 inch
legs are not used. Counter must be made of a noncombustible material such as
metal or tile.
INITIAL START-UP
WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF
THE UNIT. STEAM CAN CAUSE BURNS.
START-UP
After the Boilerless Steamer has been installed, test it to ensure that the unit is
operating correctly.
1. Remove all literature and packing materials from the interior and exterior of
the unit.
2. Make sure the water supply line is open.
3. Turn on electrical service to the unit. The steamer will not operate without
electrical power. Do not attempt to operate the unit during a power failure.
NOTE: The door MUST be closed for the burner to work.
4. There is an on/off switch in the rear of the unit. Confirm that is it in the ON
position.
5. To turn the unit on, press the power button on the front control panel. The
power button will light up and the touch screen will display that the unit is
going through self diagnostics.
NOTE: DELIME button is only displayed
during startup if the DELIME button is
turned to ON in settings menu. The
default setting for DELIME button is OFF.
12:00pm
Performing self-diagnostic
12:00pm
Performing self-diagnostic
Delime
+1m